Please read first symbols This operating manual provides important information The following symbols are used in the operating manual. on the handling of the unit. It is an integral part of the They have the following meaning: product and must be stored so that it is accessible in the immediate vicinity of the unit.
Intended use safety and security The unit may be used only for the intended purpose. The unit is operationally safe when used for the intend- That means: ed purpose. The construction and design of the unit con- form to the state of the art, all relevant dIN/vdE regu- •...
Customer services attentIon for safety reasons: Never disconnect the unit from the power sup- for technical information please contact a qualified tech- ply, unless the unit is being opened. nician or the manufacturer's local partner. overview “customer service”. attentIon Install the heat pump only indoors and operate only with outside air as the heat source.
Operating principleof heat Heat quantity recording pumps In addition to the proof of the unit's efficiency, EEWaer- meGalso meets the demand for a heat quantity recording Heat pumps operate on the principle of a refrigerator: (hereafter refered to as HqR). The HqR is mandato- the same technology, only with the opposite effect.
Cleaning and rinsing of unit Components The outer surfacesof theunit can be cleaned with a damp cloth and household cleaning products. do not use cleaning or care products that contain abra- WarnIng! sives, acids and/or chlorine. Such products would de- unit components may be cleaned and stroy the surfaces and could also damage the technical rinsed only by customer service personnel...
scope of delivery proceed as follows: Example of scope of delivery: Inspect delivery for outwardly visible signs of dam- age. view 1: check to make sure that delivery is complete. Any defects or incorrect deliveries must be claimed immediately. notIce. Note the model.
Installation and assembly transport to installation loCation To prevent damage during transport, always transport observe the following when performing all work: the unit to final installation location in its original packag- ing, using a lifting truck. notIce. Always comply with applicable accident pre- notIce.
Page 10
The lW 140(l) and lW 180(l) units can be lifted with " and/or 1" pipes (provided by customer) that are suit- able for the weight of the respective unit. Special holes are provided in the frame for this purpose.
Page 11
proceed as follows: lift the unit on the pipes with at least four people and carry it to its final installation location… Remove lower facing panels on the fan side of the unit. To do so, loosen quick-release screws. Turn counter- WarnIng! clockwise 90°…...
Page 12
Slant the facing panel upwards, remove and set aside push the fan in the direction of the evaporator up in a safe place… to the top metal tab inside the unit… 1 top metal tab inside the unit Then remove side facing panels from the unit too and store safely…...
installation mounting the air duCts Set the unit on a stable, solid and level, preferably sound- notIce. insulated surface. make sure that the foundation is de- signed for the weight of the heat pump. Note the air blow-out direction of the unit. –...
Page 14
notIce. mount the wall ducts 1 cm above the finished outer facade. Rotate the already-interlocked parts 90° and affix the final piece at the bottom... 1 masonry of the house exterior 2 Insert the wall duct in the masonry (1 cm above the finished outer facade) or retrofit (using foam in the masonry): Rotate the already-interlocked parts by 90°...
Page 15
The interlocking of the air ducts is carried out Stick the adapter base included with delivery on the as described in the section – entitled "Wall edge of the air duct... duct(s) assembly". position the air duct on the respective opening of the air intake side...
Set the weather / rain guards on the assembly frame notIce. in the wall duct and screw down... The screen frame has no function, it is included solely to provide an optically attractive transi- tion to the wall duct. wire mesh grille and weather / rain guards assembly proceed as follows: Remove the wire mesh grille and the weather / rain...
WarnIng! “Hydraulic connection” instructions. the condenser may be rinsed only by cus- tomer service personnel authorized by the manufacturer. notIce. check to make sure that the diameters and connect the unit to the pipes of the heating cir- lengths of the pipes for the heating circuit are cuit via vibration decouplers.
Circulating pumps discharge of the condensate into the sewage system is permitted only via a funnel siphon, which must be acces- sible at all times. attentIon Always note the model. Pressure relief do not use regulated circulating pumps. circulating pumps and domestic hot water circu- lation pumps must be multi-stage pumps.
electrical connections sor through the rubber sockets on the facing panel in the unit… observe the following when performing all work: • cut out the rubber sockets on the facing panel… Danger! for positioning of the rubber sockets for insert- Danger of fatal injury due to electric cur- ing the wires, see "dimensional drawing"...
The guide values of vdI 2035 part I and part II must notIce. therefore be complied with as minimum requirements The control element of the heat and heat pump for proper operation of the systems. our practical regulator can be connection with a computer experience has shown that the safest and most trouble- or network using an network cable designed free running of the systems is achieved with so-called...
Page 21
and in addition, fur cannot form in the boiler. This is the water softening to vdi 2035 – part i ideal approach for closed heating circuits, in particular, If the water is softened before the heating is filled, in because low oxygen input into the heating circuit can accordance with the vdI 2035 guidelines, no scale also be tolerated.
Insulating the hydraulic 4 hooks are located on the back side of the control el- ement and can be used to hang the control element on connections the front facade of the unit: Insulate the vibration decouplers and the pipes of the heating circuit.
Installation and removal of the Stick the heating and heat pump regulator's control cable into the right bushing on the bottom of the screen control element… installing the sCreen notIce. The screen is provided at the time of delivery so that the control element may be inserted in the upper recesses of the front facade.
Commissioning beginning first on one side and moving upwards, lock the screen's snap-in lugs in place in the slots provided on the front of the facade… Danger! the unit may be commissioned only with the air ducts and weather grille or rain guard installed and with the covers closed.
Dismantling safety temperature limiter A safety temperature limiter is built into the electric heating element (depending on model). In the event of a Danger! malfunction in the heat pump or air in the system, check Danger of fatal injury due to electric cur- whether the reset button of the safety temperature lim- rent! iter has tripped.
Dimensional drawings LW 140 – LW 180 • LW 180H 4x M8 1780 1620 1578 4x M8 1620 1578 Legend: UK819355a All dimensions in mm. Legende: D819355a Technische Änderungen vorbehalten. Front view Alle Maße in mm. Side view from left...
Page 36
Lw 140L – Lw 180L Dimensional drawings 4x M8 1780 1620 1578 4x M8 1620 1578 Legend: UK819356 Legende: D819356- All dimensions in mm. Technische Änderungen vorbehalten. Alle Maße in mm. Front view Side view from left Vorderansicht Seitenasicht von links Side view from right Seitenansicht von rechts Rear view...
Installation plan version 1 LW 140(L) – LW 180(L) • LW 180H 1020 ≥800 ≥800 > 2965 Item Designation Dim. Legende: UK819336b-1 With finished wall thickness 240 to 320 2340 All dimensions in mm. With finished wall thickness 320 to 400...
LW 140(L) – LW 180(L) • LW 180H Installation plan version 2 1020 ≥800 ≥800 > 2925 Item Designation Dim. Legende: UK819336b-2 With finished wall thickness 240 to 320 2340 All dimensions in mm. With finished wall thickness 320 to 400...
Installation plan version 3 LW 140(L) – LW 180(L) • LW 180H 2023 1020 1020 ≥800 ≥800 >3430 Item Designation Dim. Legende: UK819336b-3 With finished wall thickness 240 to 320 All dimensions in mm. With finished wall thickness 320 to 400...
LW 140(L) – LW 180(L) • LW 180H Installation plan version 4 3023 1020 1020 ≥800 ≥800 > 4430 Dim. Item Designation Legende: UK819336b-4 With finished wall thickness 240 to 320 All dimensions in mm. With finished wall thickness 320 to 400...
Dimensional drawings Lw 251 – Lw 310 4x M8 1887 1763 1718 4x M8 1763 1718 Legend: UK819357b All dimensions in mm. Legende: D819357b Technische Änderungen vorbehalten. Front view Alle Maße in mm. Side view from left Vorderansicht Side view from right Seitenasicht von links Rear view Seitenansicht von rechts...
Lw 251L – Lw 310L Dimensional drawings 4x M8 1887 1763 1718 4x M8 1763 1718 Legende: D819358b Technische Änderungen vorbehalten. Legend: UK819358b Alle Maße in mm. All dimensions in mm. Vorderansicht Front view Seitenasicht von links Side view from left Seitenansicht von rechts Rückansicht Side view from right...
Installation plan version 1 Lw 251(L) – Lw 310(L) 1020 ≥800 ≥800 > 2965 Legende: 819337 Pos. Bezeichnung Technische Änderungen vorbehalten. Zubehör: Wanddurchführung 1000x1000x420 Alle Maße in mm. Zubehör: Luftkanal 900x900x1000 Zubehör: Luftkanalbogen 900x1050x1450 Legend: UK819337a-1 All dimensions in mm. Pos.
Lw 251(L) – Lw 310(L) Installation plan version 2 1020 ≥800 ≥800 > 2965 Legende: 819337 Pos. Bezeichnung Technische Änderungen vorbehalten. Zubehör: Wanddurchführung 1000x1000x420 Legend: UK819337a-2 All dimensions in mm. Alle Maße in mm. Zubehör: Luftkanal 900x900x1000 Zubehör: Luftkanalbogen 900x1050x1450 Item Designation Dim.
Installation plan version 3 Lw 251(L) – Lw 310(L) 2023 1020 1020 ≥800 ≥800 >3430 Legende: 819337 Pos. Bezeichnung Technische Änderungen vorbehalten. Zubehör: Wanddurchführung 1000x1000x420 Legend: UK819337a-3 All dimensions in mm. Alle Maße in mm. Zubehör: Luftkanalbogen 900x1050x1450 Einbau über Erdgleiche: Item Designation Dim.
Lw 251(L) – Lw 310(L) Installation plan version 4 3023 1020 1020 ≥800 ≥800 > 4430 Legend: UK819337a-4 All dimensions in mm. Legende: 819337 Pos. Bezeichnung Item Designation Dim. Technische Änderungen vorbehalten. Zubehör: Wanddurchführung 1000x1000x420 Alle Maße in mm. Zubehör: Luftkanal 900x900x1000 With finished wall thickness 240 to 320 Zubehör: Luftkanalbogen 900x1050x1450 With finished wall thickness 320 to 400...
Customer service addresses in the event of a serviCe Call for a current list and additional partners of the manufacturer, please visit www.alpha.innotec.com. Ticino Alpha-InnoTec Österreich ait-schweiz AG oy callidus Ab Eco-Wp via alla Torre 2 Hiekkakiventie 1 Wärmepumpenhandelsges. m.b.H 6850 mendriso 00710 Helsinki Währingerstr.
Page 71
Lt/Lv UAb TENKo baltic bjärneroth Teknik basanaviciaus g. 45 Evas väg 5 03109 vilnius 280 64 Glimåkra Tel.: +370 526 435 82 Tel.: +46 (0) 708 420 544 fax: +370 526 435 83 fax: +46 (0) 444 222 0 info@tenko.lt bjarneroth@telia.com www.tenko.lt www.btait.se...