Connecting The Priming Components; Priming Pump And Priming Valve - Waterous VPO Priming System Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Safety
Introduction

Connecting the Priming Components

Product Overview
3
4
|
45
56
Installation
Operation

Priming Pump and Priming Valve

Use the illustration and instructions to make the
connections on a single priming pump and single
priming valve application.
1 Install the outlet muffler if it is suitable to your
application. Alternatively, locally source the
components required in your application to
direct the priming-pump exhaust away from
people to avoid injury and equipment to avoid
damage.
Note: Make sure to use a minimal bend radius
and arrange the hose to allow proper
draining.
2 Install a 3/4-inch NPT fitting with a 3/4-inch
hose connection to the priming pump inlet.
3 Install a 3/4-inch NPT fitting with a 3/4-inch
hose connection to the priming valve outlet.
4 Use an appropriate hose to connect to the
fittings on the priming pump and priming valve.
Refer to:
on page 25
Make sure that you install the hose so that it
drains from the priming valve to the priming
pump.
2
1
Maintenance
"Hose and Tubing Requirements"
to select the appropriate hose.