Dual Priming Pumps—24V
Use the illustration and instructions to connect the a
dual priming pump application to apparatus power.
Refer to F-2825 Wiring Best Practices instruction,
available at waterousco.com.
Include the following when installing the priming
pump:
• The 12V priming pump draws 325 amps of current
and the 24V priming pump draws 170 amps of
current. Make sure your wiring is rated for the
current draw in your application.
• Make sure that you include adequate circuit
protection.
• It is recommended that you isolate the priming
pump power and ground circuits for best
performance.
• Provide flyback voltage protection if required by
your application.
1 Connect apparatus power to the priming pump
power terminal. Make sure that you include an
appropriately sized breaker in the circuit. Torque
the nut on the priming pump to 4.5 ft-lb (6 N∙m).
2 Connect a ground strap from the priming pump
ground terminal to the apparatus frame.
3 Connect apparatus ground to the priming pump
ground terminal. Torque the nut on the priming
pump to 4.5 ft-lb (6 N∙m).