  • Page 1 Instruction manual • Mode d´emploi • Istruzioni d’uso Instrucciones para el servicio • Gebruiksaanwijzing Instrukcja obsługi • Инструкция по эксплуатации • • • Renfert GmbH • Industriegebiet • 78247 Hilzingen / Germany Tel. +49 7731 8208-0 • Fax +49 7731 8208-70 info@renfert.com • www.renfert.com Made in Germany...
  • Page 2: Application Area

    Observe the operating instructions. 2.1 Ambient Conditions 3.2 Hazard Information (in accordance with DIN EN 61010) • The Twister venturi is an electric unit and, as The unit may only be operated: such, carries with it a certain inherent potential •...
  • Page 3: Commissioning, Operation

    4. Adjust the desired speed 4.2 Benchtop Units >>> 100 - 400 rpm (Figure 16). The Twister venturi can be operated as a benchtop 5. Adjust the desired mixing time >>> 0 - 5 min. (Figure 17). unit when a stand is employed.
  • Page 4 When power is restored or the unit is again nance tasks. switched on, the mixing motor WILL NOT The Twister venturi mixing unit is practically mainte- automatically restart itself. nance-free. Nonetheless, the inlet fi lter and the seals should be cleaned regularly as part of a preventative mainte- nance programme.
  • Page 6: Standard Delivery

    11. Delivery Versions No. 1820-0710 Blunger, 700 ml No. 1820-0720 Bowl, 700 ml No. 1824-0000 Twister venturi 230 V / 50-60 Hz, incl. 500 ml-bowl with blunger No. 1820-1001 Bowl, incl. blunger, 1000 ml No. 1824-1000 Twister venturi 120 V / 50-60 Hz, incl.
  • Page 7: Troubleshooting

    13. Troubleshooting Problem Possible cause Corrective action • Power not connected. • Check the power supply. ON/OFF switch fails to work. • Device fuse blown. • Replace the fuse (refer to Sec. 6.4). • Damaged power cord. • Have the device repaired. •...
  • Page 8 (0.3546 - 0.394 inch)

This manual is also suitable for: