Download Print this page

Full Specifications - Heatrae Sadia Hotflo Quick Start Manual

Advertisement

Full specifications

Specification
Capacities
10 and 15 litres.
Rating
2.2kW @ 240V, (2kW @ 230V).
Outer casing
White plastic top moulding with steel base and centre
section, finished in white stove enamel.
Thermal insulation
CFC/HCFC free (ODP zero) flame-retardant expanded
polystyrene.
Water container/integral heat unit
Replaceable heavy gauge copper inner container,
designed for 6 bar working pressure and type tested
to 20 bar (290 psi), with embedded rod-type element
sheathed in corrosion resistant alloy.
Thermostat
Rod-type externally adjustable from 10°C to 70°C.
Safety features
Pressure relief valve set to open at 6 bar.
Resettable over temperature cut-out.
Anode
Not required.
IPX4 rated
Approvals
Kiwa approved to UK water supply regulations.
CE marked. Manufactured in the UK in a BS EN ISO
9001:2000 registered factory.
6
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
Installation
Mechanical
Must be mounted in the vertical position with inlet /
outlet at the top. Floor or wall-mounted (three screws
/ keyhole slots).
Plumbing
15mm copper tail ends. Minimum water pressure 0.8
bar (12 psi). For pressures above 4.1 bar (60 psi), packs
U1 and U5 must be used.
NOTE: The pressure relief valve supplied must always
be fitted. See accessory selection guide on page 4.
Temperature and pressure relief valve
Optional Pack U6 – see accessory selection guide on
page 4.
Safety valve discharge
The pressure relief (expansion) valve or temperature
& pressure relief valve (if used) must be plumbed to
discharge in a safe visible location.
Optional thermostatic blending valve
Accessory Pack U3 and Pack U7 (see page 5) allows
water to be stored at high temperature and blended
with cold to a preset outlet temperature.
Electrical
The unit must be permanently connected to the
electrical supply through a double-pole linked switch
with minimum breaking capacity of 13 amps.
Must conform to current IEE wiring regulations.
Guarantee
Hotflo carries a full two year transferable on-site
service support guarantee against faulty manufacture
or materials provided that:
It has been correctly installed as per the
instructions contained in the instruction manual
and all relevant Codes of Practice and Regulations
in force at the time of installation.
It has been installed in the UK.
It has not been modified in any way, other than by
Heatrae Sadia Heating.
The damage is not due to scaling or frost.
It has only been used for the storage of potable
water.
It has not been tampered with or been subjected
to misuse or neglect.
Within 60 days of installation the user completes
and returns the certificate supplied along with the
proof of purchase to register the product.
Evidence of purchase and date of supply must be
submitted. The unit is not guaranteed against
damage due to frost. The guarantee is transferable.
This guarantee does not affect your statutory rights.