Download Print this page

Mounting On A Drop-Ceiling T-Bar; Mounting On A Flat Surface - CommScope RUCKUS R760 Quick Setup Manual

Advertisement

FIGURE 4 Allowing the Cable Between the T-bar and Ceiling Tie
3. Secure the eyelet end of the safety cable to the AP with the M3 x 8-
mm screw.
NOTE: Torque screw to 7 in-lbs.
FIGURE 5 Attaching Security Cable to AP
Copyright
©
2022 CommScope, Inc. All rights reserved.
Published April 2022, Part Number 800-72756-001 Rev A
4. Attach the AP to the T-bar mounting bracket and tuck any excess
safety cable between the AP and ceiling tile so that it is hidden from
view.
NOTE: Do not let the safety cable run near the plastic white cover
as it may affect the antenna performance.
FIGURE 6 Tucking Excess Cable

Mounting on a Drop-Ceiling T-Bar

The factory-supplied T-bar mounting assembly kit allows you to attach the
AP to recessed and flush drop-ceiling T-bars.
1. Position the studs on the bottom of the T-bar bracket (1 in
the keyholes on the AP enclosure.
2. Slide the T-bar bracket away from the Ethernet ports on the bottom
of the AP until the AP retainer tab (2) snaps into place, trapping the T-
bar bracket studs in the keyholes (3).
FIGURE 7 Attaching the T-bar Bracket to the AP
3. Insert the locking tabs (4) so they are in the first position on the T-bar
bracket.
4. Gently push the ceiling tiles, if present, up and out of the way.
5. Align the centerline of the bracket or AP with the centerline of the T-
bar. Push the four locking tabs toward the T-bar until they grip the
edges of the T-bar and seat in their locked positions.
After installation, the centerline of the AP should be aligned with the
centerline of the T-bar.
FIGURE 8 Attaching the T-bar Bracket to the T-bar

Mounting on a Flat Surface

The factory-supplied mounting screws and plastic wall anchors allow you
to attach the AP to a wall or other flat surface.
1. Use the Mounting Template on the last page of this Quick Setup
Guide to mark the locations for two drill holes on the mounting
surface.
2. Use a 4.75-mm (3/16-in.) drill bit to drill holes approximately 25 mm
Figure
7) in
(1 inch) deep into the mounting surface.
3. Insert the factory-supplied anchors (1 in
screws (2 in
Figure
9) into the mounting surface, leaving
approximately 6 mm (1/4 inch) of the screw heads protruding for the
AP enclosure.
FIGURE 9 Flat Surface Mounting
4. Place the AP onto the mounting screws so the screw heads enter the
keyholes on the AP enclosure, and push the AP down until the AP
retainer tab snaps into place.
Figure
9) and mounting
Page 3 of 5

Advertisement

loading