Halma SENSITRON GALILEO 32 Manual

Halma SENSITRON GALILEO 32 Manual

Gas contro panel for addressable gas detectors

Advertisement

Quick Links

SENSITRON
GALILEO 32
A Halma Company
Manuale/Manual
MT2276E REV2 18/05/2018©
Sensitron S.r.l., Viale della Repubblica 48, Cornaredo (MI)
sales@sensitron.it
TEL. +390293548155 FAX. +390293548089
GALILEO 32
Gas contro panel
for addressable gas detectors
Manuale / Manual
MT2276E
SENSITRON S.R.L. - All rights reserved - www. sensitron.it

Advertisement

loading

Summary of Contents for Halma SENSITRON GALILEO 32

  • Page 1 SENSITRON GALILEO 32 MT2276E A Halma Company Manuale/Manual SENSITRON S.R.L. - All rights reserved - www. sensitron.it GALILEO 32 Gas contro panel for addressable gas detectors Manuale / Manual MT2276E REV2 18/05/2018© Sensitron S.r.l., Viale della Repubblica 48, Cornaredo (MI) sales@sensitron.it...
  • Page 2 SENSITRON MT2276E Manuale/Manual A Halma Company GALILEO 32 P. 2/14 P. 3 Introduction P. 5 Installation P. 10 System power up and operation P. 16 User levels P. 17 Menu’s details P. 27 PC configuration software This manual must be carefully read by all persons who have or will have the responsbility for installing, using or servicing this product. Like any equipment, this product will perform as designed only if installed, used and serviced in accordance with the manufacturer’s instructions.
  • Page 3 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 3/14 1. Introduction The present manual explains the procedures for installing, operating and pro- gramming, as well as some aspects related to the commissioning and mainte- nance for the control unit Galileo 32.
  • Page 4: Power Consumption

    SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 4/14 TECHNICAL SPECIFICATIONS Housing Metal cabinet 430 x 405 x 140 mm. Inputs Max. 32 detectors type SMART “S” on 1 x RS485 closed bus Outputs 8 relay board mounted in the control panel...
  • Page 5: Installation

    SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 5/14 2. Installation CONTROL UNIT Installation cabinet: IP20 minimum. Devices installed in zone that have been classified and connected to control unit shall be protected with one of the types of protection listed in EN 60079-0, corre- sponding to their own category.
  • Page 6 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 6/14 Figure 2.1 b) Power supply and battery connection details GAS DETECTORS GALILEO 32 gas control panel can be connected to Sensitron’s SMART “S” de- tector version. Detectors are to be duly installed according to the gas to be detected and in ful- filment of all EU or national rules in force.
  • Page 7 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 7/14 LAYOUT OF THE CONTROL UNIT MAIN BOARD All connections of the GALILEO 32 control panel are to be performed on the main board. See below the layout. Figure 2.3...
  • Page 8 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 8/14 Figure 2.5 Detector connections RELAY OUTPUT CONNECTION For the programming of the relays functions, the PC software is required. Any- way, the relays 1, 2 and 3 are already set to trigger for System Fault (Relay 1 re- dundant with Relay 2) and for Emergency (Relay 3).
  • Page 9 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 9/14 SERIAL CONNECTION TO A PERSONAL COMPUTER The control panel can be connected to a Personal Computer using the RS485 serial port, to permit initial programming. Below the connection to the Personal Computer.
  • Page 10 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 10/14 POWER ON After ensuring correct installation of the Galileo 32, the unit can be switched on. When first switched on, after the “Warm Up” time (3 minutes by default – pro-...
  • Page 11 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 11/14 SYSTEM STATES The system is designed so that it may be at a certain moment in one of following operating modes, which will be comprehensively explained in the following chapters:...
  • Page 12 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 12/14 NORMAL This is the system state when everything works properly and there is no Alarm and no Fault notification. Under this condition it is possible to visualise the cur- rent status of the inputs.
  • Page 13 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 13/14 Pressing Enter key, with a certain alarm event selected, a window is opening showing the details of the related channel as in the next image: Figure 3.4 b) ALARM details screen At any access level, by selecting in the main window the 1—Menu and than AC-...
  • Page 14 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 14/14 Pressing Enter key, with a certain fault event selected, a window is opening showing the details of the related channel as in the next image: Figure 3.5 b) FAULT details screen TEST/MAINTENANCE This state is meant for testing and maintenance purpose.
  • Page 15: User Levels

    SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 15/14 EMERGENCY MODE Special defined state in which the systems switches in case of main unit mal- functioning or in case of degrading of SIL level, during operation, due to system faults that may occur.
  • Page 16 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 16/14 In the bottom of the screen, for the “Operator” level there are available the fol- lowing options: MENU, gets the user into a sub menu LOGOUT, logs out the active user LOGIN, opens the login dialogue window * See next chapters for details.
  • Page 17 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 17/14 WINDOW IN 1 MENU NORMAL MODE GALILEO 8/32 CONTROL PANEL Sensitron Srl 12.34 Sensitron Srl 12.34 Sensitron Srl 12.34 Sensitron Srl 12.34 ALARM CHANNELS EVENT CHN UNIT CONC STAT...
  • Page 18 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 18/14 Figure 5.1.1 a) Active Events screen with Alarm and fault Should there are just Alarms or just Faults/Emergency situations they will be shown in the upper side of the window, respectively.
  • Page 19 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 19/14 Pressing 1 ACK with the cursor on the active event, will acknowledge it. There are two situations: The user is already logged in for a previous operation that requires login.
  • Page 20 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 20/14 SELECT PERIOD Opens a query asking to select the period to be observed by entering the start and the end date. Figure 5.1.2 b) Select period dialogue window The date should be introduced in a 2 digit format for day, month and year: “DD/ MM/YY”.
  • Page 21 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 21/14 SETTINGS Choosing the Settings LOG option enters the Settings events list. Using the up/down arrow keys one may search in the Settings event log. ALARMS Choosing the Alarms LOG option enters the Alarm events list.
  • Page 22 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 22/14 Figure 5.1.3 c) Relay screen options By the options of this screen, unlike the Operator level, the “Maintenance” level and the “Engineer” level may: Put in Set or Unset the selected relay...
  • Page 23 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 23/14 The relays in TEST status can be activated and deactivated by the op- tions 2-ACTIVATE and 4-DEACTIVATE. The EXIT TEST option takes out of the Test/Maintenance mode the se- lected relay.
  • Page 24 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 24/14 By the options of this screen, unlike the Operator level, the “Maintenance” level and the “Engineer” level may: Put in Set or Unset the selected channel Put in Test/Maintenance and take out of Test/Maintenance the select-...
  • Page 25 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 25/14 5.1.5 SYSTEM INFO At any user level, choosing the SYSTEM INFO menu option will show a window with the information about the hardware and the software versions: Figure 5.1.5...
  • Page 26: Pc Configuration Software

    SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 26/14 Figure 5.4 Login dialogue window Note After login, in the right and upper corner of the screen one should know what user level is it: “O” for Operator, “M” for Maintenance and “E” for Engineer.
  • Page 27 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 27/14 The login window will appear. Each user must be authorised to use the program. See chapter “Application User Management” in this manual to create users with relevant permissions. The first time the program is used after installation, the only user set is Sensi- tron with a default password.
  • Page 28 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 28/14 Figure 6.3.1 b) Panel selection screen Select the panel: Galileo 32 Note for Galileo 32 panel do not use the Auto Detection but select manually the panel Galileo 32.
  • Page 29 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 29/14 New configuration To create a new system configuration Open file To open an existent configuration Serial port To set a PC serial port for data transfers to and from the connected CPU Test To test PC serial >...
  • Page 30 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 30/14 Figure 6.4.1 b) Open an existent system file Open Event Log File to display event log files previously loaded from the CPU (Menu: Communication, Submenu: Upload Event Log from CPU).
  • Page 31 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 31/14 Figure 6.4.1 e) Event log screen For information on reading the event log, see: Menu: Communication Submenu: Upload Event Log from CPU. Click “Save” to save changes to the system.
  • Page 32 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 32/14 Figure 6.4.1 g) System file comparison window Click “Save As” to save the system file with a new name Click “Close” to close the open system file Click “Exit” to exit the GALILEO 32 program 6.4.2...
  • Page 33 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 33/14 Figure 6.4.3 b) User settings window The first time the program is used after installation, the only user installed is Sensitron with default password 543210. Sensitron is an administrator level user which is the highest level and permits access to all program functions.
  • Page 34 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 34/14 Figure 6.4.3 d) User Permissions settings window Flag the various boxes to enable the relevant function for the user. Click “Set De- fault”, according to the user level being set (Level 1, 2 or 3), a preset selection of enabled functions are automatically assigned to the user (which can always be edited).
  • Page 35 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 35/14 Figure 6.4.3 f) Log Application window 6.4.4 COMMUNICATION Figure 6.4.4 a) Menu communication The “Communication” menu includes options for data transfers between the PC software and the GALILEO 32 control panel...
  • Page 36 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 36/14 The connection with the PC will be made by means of a serial port connected to Galileo 32 through the related cable (see Fig. 6.4.4 b above), connected at JP18 Checking the connection (test command) “Test Command”...
  • Page 37 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 37/14 Before starting the data upload and download procedure, a warning message appears asking if you want to save the control panel event log. When a new con- figuration is downloaded with different data (new gas detectors, zones and sys- tem modules, new users, etc.) the control panel event log may no longer be real.
  • Page 38 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 38/14 After entering the password, the event log file starts uploading and this operation may take up to one minute. When uploaded, in addition to being automatically saved in the PC default folder: c:\Documents and settings \ user \ Documents \ GALILEO 32 \ Logs, events are also displayed in the specific window.
  • Page 39 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 39/14 Event More detailed description of the event type Value Gas concentration value (for an alarm event) Unit Gas detector unit of measure User User ID for user events (Ack, Reset,Login etc.)
  • Page 40 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 40/14 MODIFICATION OR CREATION OF A NEW CONFIGURATION FILE Via the “Open” command in the “File” menu existing configuration files will be in- dicated and may be chosen and opened.
  • Page 41 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 41/14 In the “General Settings” it is indicated: Warm Up Time The warm-up time for the system after which it passes over to measuring mode (from 2 to 10 minutes; default 3 minutes)
  • Page 42: Module Description

    SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 42/14 Figure 6.5.4 a) Videata periferiche (Moduli Input) Input Modules STG/IN8-S analog input modules installed in the system are set in Input Modules. Click Add Input Module to open the window shown in Fig. 4.5.4 b.
  • Page 43 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 43/14 Sensors Gas Detectors installed in the system and directly connected on the bus (RS485 bus) are set in “Sensors”. Refer to chapter 2-Installation for further information. Click Sensors to open the window shown in Fig. 6.5.4 c.
  • Page 44 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 44/14 Output Modules STG/OUT16 output modules installed in the system are set in Output Module. Click Add Output Module to open the window shown in Fig. 6.5.4 d. Figure 6.5.4...
  • Page 45 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 45/14 6.5.5 CHANNELS Use the “Channels” menu to enable and program single gas Detector settings in the system. Channels Overview Figure 6.5.5 a) Channels map screen The Channel Overview gives a quick overview of how many Input modules and detectors are programmed in the GALILEO 32 configuration and these are de- fined.
  • Page 46 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 46/14 Channel Manage Figure 6.5.5 c) Channel details screen Specifying a new input-channel An input channel is specified by the combination of three different drop down lists. The “Profile” specifies the measurement task, related to the gas. e.g.
  • Page 47 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 47/14 The available Profiles are: L.E.L. OXYGEN DEFICENCY OXYGEN ENRICHMENT OXYGEN FOR INERTIZATION OXYGEN MIXED MODE TOXIC The “Gas Type” represents the list of gases belonging to the related “Profile”. Choose the right gas as for the gas detector connected to the input.
  • Page 48 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 48/14 The left arrow going upwards is indicating the “increasing alarms” of the LEL pro- file where the alarm levels from alarm 1 to alarm 3 correspond to increasing con- centration.
  • Page 49 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 49/14 Figure 6.5.5 f) Redundancy tab in the channel definition screen Specifying a new redundant channel The channel 1 of module 1 has been defined. After finishing the configuration of the channel the TAB “Redundancy”...
  • Page 50 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 50/14 Figure 6.5.5 g) List for choosing the redundant channel Chose the Redundant channel and confirm by Accept. If the chosen Redundant channel has a different configuration, the configuration will be automatically modified, matching the configuration of the other channel (a...
  • Page 51 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 51/14 6.5.6 RELAY OUTPUTS Via the menu “Relay”, the characteristics of the outputs on the remote output modules STG/OUT16 S being part of the system are enabled and programmed. Relay overview Figure 6.5.6...
  • Page 52 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 52/14 Relay Output Manage Figure 6.5.6 c) Outputs details screen The Relay Output Manage screen allows programming the event(s) that activate the outputs. Available options are as follows: Events: to program the event and the output to activate Redundancy: in systems where a higher safety level is requested, 2 outputs can be used for the same activation.
  • Page 53 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 53/14 Add / Remove: To add or remove the events from the Associated Sensors Modules window. Programming of a new Relay Output: Selecting the new output, by the Relay Type mode select if it is a Sensor event, a Module event or a Generic event.
  • Page 54 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 54/14 Figure 6.5.6 f) Output setting summarizing screen It is not possible to select different types of events associated to just one output. An output set for the Alarm 1 cannot be set for the Alarm 2 or 3 as well.
  • Page 55 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 55/14 OR and Voting functions Figure 6.5.6 i) OR and Voting functions OR function By selecting OR, a single event (between the events shown in the Associated Sensors summarizing screen) is enough to activate the output.
  • Page 56 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 56/14 After associating the output (sensors) to the respective channels choose the Voting (And) option. The “Voting Setting” window will appear in the middle of the monitor. Select the number (quantity) of the events that have to activate contem- poraneously in order to activate the selected output.
  • Page 57 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 57/14 How to program a Redundancy Output. The output 1 of module 5 has been defined. After finishing the configuration of the relay the TAB “Redundancy” is chosen. Because actually no redundant relay is specified, the information within the TAB is empty (bottom left of Fig.
  • Page 58 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 58/14 Figure 6.5.6 m) Outputs details screen showing a defined relay with redundancy Outputs “Operation Mode” There are three options for the output Operation Mode Figure 6.5.6 n) Output operation mode...
  • Page 59 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 59/14 Steady follows the course of the alarm; alarm activated, output activated after a possible activation delay; alarm restored, output low after a possible de-activation delay. Pulsed flashing mode with the ON and OFF times adjustable...
  • Page 60 SENSITRON MT2276E Manual (EN) A Halma Company GALILEO 32 P. 60/14 The Normally Energized option defines if the output is normally activat- ed or not, in normal operation. Figure 6.5.6 o) Outputs “Operation Mode” windows The above information do not make the manufacturer liable, and the manufacturer reserves the right to make any changes that it retains will be useful to...
  • Page 61 SENSITRON GALILEO 32 MT2276E A Halma Company Manuale/Manual SENSITRON S.R.L. - All rights reserved - www. sensitron.it Contatti/Contacts Viale della Repubblica, 48 20007 Cornaredo (MI) – ITALY +39 0293548155 sales@sensitron.it sensitron.it Sensitron S.r.l. MT2275E REV2 Sensitron S.r.l., Viale della Repubblica 48, Cornaredo (MI) sales@sensitron.it...