Kohler GM87448 Operation page 20

Industrial generator set
Table of Contents

Advertisement

Parameter Name
Battery Type
Charger Maximum
Default 12 V
Absorption Time
Default 24 V
Threshold (Min.)
FLA 12 V
FLA 24 V
AGM 12 V
AGM 24 V
Gel 12 V
Gel 24 V
NiCad 12 V
NiCad 24 V
Charger Maximum
Default 12 V
Bulk Time Threshold
Default 24 V
(Min.)
FLA 12 V
FLA 24 V
AGM 12 V
AGM 24 V
Gel 12 V
Gel 24 V
NiCad 12 V
NiCad 24 V
Charger Refresh
Default 12 V
Charge Cycle Time
Default 24 V
(Hr.)
FLA 12 V
FLA 24 V
AGM 12 V
AGM 24 V
Gel 12 V
Gel 24 V
NiCad 12 V
NiCad 24 V
Charger Equalize
Default 12 V
Stage Duration (Min.)
Default 24 V
FLA 12 V
FLA 24 V
AGM 12 V
AGM 24 V
Gel 12 V
Gel 24 V
NiCad 12 V
NiCad 24 V
Charger Charge
Default 12 V
Cycles Between Auto
Default 24 V
Equalize Cycles
FLA 12 V
FLA 24 V
AGM 12 V
AGM 24 V
Gel 12 V
Gel 24 V
NiCad 12 V
NiCad 24 V
20
Range
Default Settings
60 – 360
240
60 – 360
240
60 – 360
240
60 – 360
240
60 – 360
240
60 – 360
240
60 – 360
240
60 – 360
240
60 – 600
240
60 – 600
240
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
60 – 600
480
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
0, 23 – 672
335
Not available
Not available
Not available
Not available
60 – 480
360
60 – 480
360
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
0 – 99
0
0 – 99
0
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Description
The setting for the maximum amount of time
the battery attempts to complete the
absorption cycle. Inability to complete
absorption with properly adjusted absorption
parameters may indicate a battery with
reduced capacity.
The setting for the maximum amount of time
the battery attempts to complete the bulk
cycle.
The setting for the amount of time between
refreshing the battery by charging though or
completing a charge cycle.
The setting for the maximum amount of time
spent in equalize. This prevents excessive
outgassing and avoids boiling out the
battery.
When automatic equalize cycle enable is
active, this setting determines the number of
charge cycles between equalize cycles.
TP-7077
3/19

Hide quick links:

Advertisement

Table of Contents
loading