Tankless Water Heater
Figure 60
56
Condensate Pump Safety Switch Installation
To Condensate Pump
Safety Switch Wires
Field-Supplied Wires
Condensate Pump (field-supplied)
Includes internal safety switch and power cord.
Power cord must be plugged into power source.
Rinnai Tankless Water Heater Installation and Operation Manual
Wire Nut Connecting
Two Wires
Safety Switch Wires*
* Safety switch wires connect to the NO
and COM contacts on the safety switch.
COM
NO
• NO - Normally Open
• NC - Normally Closed
• COM - Common (Neutral)