Available languages

Temperature Compensation
Set Temperature Compensation:
•  With the display off, press and hold the FAN button for 5 seconds. 
The display will then show 0 (default) or current compensation set-
ting . Use TEMP+/- buttons to adjust the compensation . Compensa-
tion can be set in 1° increments
+/- 8°F (0 .5°C increments up to +/-4°C) .
• Temperature compensation changes the ambient temperature
reading . If the system is sensing the ambient temperature at 72°F
and the compensation is set to -2° then the system will use 70°F in
its operation to heat or cool .
Forced Defrost:
• Set to Heating mode, high fan, and 86°F (30°C), or highest
temperature if ECO is on . Press TEMP+ 6 times within 5 seconds .
Three tones will confirm that the unit is in forced defrost mode.
Forced Cooling:
• Set mode to Cool . Tap ON/OFF . Tap any button, except ON/OFF,
to light the display . Press and hold ON/OFF for 5 seconds . LL will
display and the control will beep twice. To exit, turn off control and 
turn it on again .
Forced Heating:
• Set mode to Heat . Tap ON/OFF . Tap any button, except ON/OFF,
to light the display . Press and hold ON/OFF for 5 seconds . HH will
display and the control will beep twice. To exit, turn off control and 
turn it on again .