Table 1: Vertical Air Handling Unit General Data.
Type
System Model
(Indoor Unit / Outdoor Unit)
Cooling Capacity (Min / Rated / Max)
(Btu/h)
Cooling Power Input
(kW)
1
EER2
SEER2
Heating Capacity
(Min / Rated / Max) (Btu/h)
Heating Power Input
(kW)
1
COP
HSPF2
Maximum Heating Capacity (Btu/h)
Outdoor 17°F (DB) / Indoor 70°F (DB)
Outdoor 5°F (DB) / Indoor 70°F (DB)
Power Input [W] @ Outdoor 5°F (WB)
Outdoor -4 °F(DB) / Indoor 70°F (DB)
Power Supply V, Ø, Hz
Outdoor Unit Operating Range
Cooling (°F DB)
Optional Wind Baffle Cooling (°F DB)
Heating (°F WB)
Indoor Unit Operating Range
Cooling (°F WB)
Heating (°F DB)
Indoor Temperature Setting Range
Cooling (°F DB)
Heating (°F WB)
EEV: Electronic Expansion Valve, IDU: Indoor Unit, ODU: Outdoor Unit. This unit comes
with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0
ft level difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and
67ºF wet bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet
bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
60ºF wet bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet
bulb (WB).
1 Power Input is rated at high speed. Cooling range can be extended from 5°F down to
-4°F using the Low Ambient Wind Baffle Kit (sold separately).
LV120HCV
LV180HCV
(LVN120HCV/
(LVN181HV4/
LVU120HCV)
LVU180HCV)
4,200 ~ 12,000 ~
6,300 ~ 18,000 ~
15,000
21,000
0.45 ~ 0.98 ~ 1.50
0.50 ~ 1.64 ~ 2.00
12.20
11.00
16
15.6
6,000 ~ 15,000 ~
8,000 ~ 20,000 ~
20,000
25,000
0.40 ~ 1.26 ~ 1.93
0.73 ~ 1.83 ~ 2.60
3.50
3.20
9.3
8.7
14,000
17,400
13,000
15,000
2,100
2,560
11,820
12,160
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
GENERAL DATA
Vertical Air Handling Unit
LV240HCV
(LVN241HV4/
LVU240HCV)
7,840 ~ 22,400 ~
26,000
0.65 ~ 2.36 ~ 2.83
9.50
15.1
9,500 ~ 24,000 ~
29,000
0.91 ~ 2.27 ~ 2.95
3.10
8.5
20,000
17,000
2,840
13,450
208-230 / 1 / 60
5 to 118
Yes (-4)
-4 to 64
57 to 77
59 to 81
65 to 86
61 to 86
2 All communication / connection (power) cable from the outdoor unit to the indoor unit
are field supplied and is to be a minimum four-conductor, 14 AWG, stranded, shielded or
unshielded (if shielded, it must be grounded to the chassis of ODU only), and must comply
with applicable local and national codes.
3 Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
4 Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and
are the same in both cooling and heating mode. These values can increase due to ambient
conditions during operation.
5 Piping lengths are equivalent.
6 12k, 18k, and 24k VAHUs are supplied with socket adapters for pipe transitions.

Specifications

LV300HCV
(LVN300HCV/
LVU300HCV)
10,500 ~ 30,000 ~
33,000
0.80 ~ 3.16 ~ 3.49
9.50
15.5
12,000 ~ 30,000 ~
34,000
1.06 ~ 2.66 ~ 3.20
3.30
9.1
25,000
22,000
3,220
18,450
9