Basic Connections

2
Network Connection
Connect the
Ethernet Port
to a
network appliance
Power Connection
In systems configured with the redundant power option, connect PWR1 and PWR2
to
separate independent power sources
supports +/-48V to +/-57V DC for the PoE output, +/-50V to +/-57V DC for the PoE+
output and +/-12 to +/-57 DC for non-PoE operations.
Warning:
• This product is intended to be UL Listed supplied by a Power Adapter or DC
power source which output complies with ES1/SELV: ambient temperature 75°C
minimum, output rating 48-57 Vdc, 5A minimum.
• If using Class I power adapter or Class I DC power source, power cord shall be
connected to a socket-outlet with earthing connection.
Seperate
Redundant Power Inputs
PWR-2 Fault
Power Outlet
or UPS
V2- V2+
Power Connection
PWR-2
+/-50 to +/-57Vdc,
PWR-1 & PWR-2 accepts
5A for PoE+
+/-48 to +/-57Vdc @ 5A
+/-50 to +/-57Vdc @ 5A
DC Power Supply
Caution:
The wiring of input terminal block shall be installed by skill person.
b. Terminal block is mating with Plug and suitable for 12-28AWG, Wire Type: Cu,
FW2. Torque value 4.5 lb-in.
Note:
The FortiSwitchRugged 112D-POE device does not support interconnectivity
to other FortiSwitchRugged 112D-POE devices using the PoE ports. Fortinet
recommends using the SFP ports to interconnect switches.
8
using an Ethernet cable
for power redundancy. The FSR-112D-POE
Seperate
PWR-1
Power Outlet
or UPS
1A@24V
V1- V1+
PWR-1
+/-48 to +/-57Vdc,
5A for PoE
and/or
DC Power Supply

Setup Options

3

Web Browser

Ethernet Port
To Connect to the GUI
1. Connect the
Ethernet
cable.
2. Configure the management computer to be on the same
interface as the FortiSwitch Rugged unit:
IP address:
192.168.1.2
Netmask:
255.255.255.0
3. Visit
192.168.1.99
in your web browser.
4. Login using username
"admin"
and
no
5.
Configure your device
and save your settings.
6.
Register your device
from the dashboard page.
subnet
as the internal
password.