Troubleshooting - Zero Appliances GF120 Installation, Service And User

Single lid chest freezer
Table of Contents

Advertisement

1.
Make sure that the electrical supply to the appliance is turned off.
2. Open the shut-off valve for the gas bottle or gas installation
3. Open flap B.
4. Keep the flame failure device knob (A) pressed in for approximately 5 seconds
to allow gas to flow to the burner.
5. Strike a match and insert into flap hole (B). While the flame is burning press
and hold the flame failure device for a further 10 seconds. The burner will now
burn with a blue flame.
6. If the flame goes out, repeat steps 4, 5 and 6 until the flame stays alight.
The appliance should be left running for a minimum of 12 hours
7.
before being loaded with products.
8.
To terminate the gas operation turn off the shut-off valve on the gas bottle or
gas installation.
USERS NOTE:
The gas safety valve knob (A) should never be depressed for periods
longer than 5 seconds with the burner unlit as this can cause a potentially dangerous build-
up of unburnt gas. If the burner does not ignite, allow sufficient time for any unburnt gas to
disperse, and then repeat the ignition steps.

TROUBLESHOOTING

IF THE APPLIANCE FAILS TO WORK:
Check the following points before calling for service:
1. That the instructions for starting the appliance have been followed.
2. The appliance is level.
Author: Rudi
Version: 2.2
5
Revision: 1.3
Revision Date: August 2020

Advertisement

Table of Contents
loading