• It is very important for the work piece to be secured against working face and set- square during
cutting operation.

5. SAFETY EQUIPMENTS

WARNING : Do not remove any of the safety equipments during operation and check whether
they are functioning properly or not.
• The machine is equipped with a lock-system to prevent the vibration of the machine upper section
(lock this at lower position during machine transport).
• The head body which carries the electric motor stands at uplifted position by the means of a special
spring.
• At stop position, sawbladeis closed by the lower guard. When sawbladeis lowered for the cutting
operation, protective guard opens up automatically.
• Machine has electromagnetic switch with two buttons; "I = start" and "O = stop".

6. PERIODICAL MAINTENANCE

• All of the moving parts should be lubricated at certain intervals in order to prevent them from wear.
• Power cable should be checked on regular basis and must be replaced if it is worn.
• Always keep the plastic handle dry, thus, you can grip it securely and prevent slippage.
• Keeping the set-squares and support parts up clean is always important.
• Clean the machine carefully with an airgun or a dry brush after the work is over. Remove all of the
sawdust and other materials away from the working surface.
• Check the condition of sawbladeregularly and sharpen it if required.
• There are two strech spring attached to the head body which carries the electric motor. Replace
these springs if they become softened or damaged in the course of working time.

7. TROUBLESHOOTING

Every machine is assembled and tested in the factory with utmost care prior to delivery. Nevertheless,
there is a short list below which classifies the possible failure causes and the corresponding corrective
actions.
1. Cutting angle failure
Cause: Set-square adjustment is wrong.
Measure: Loosen M12 screw which connects T-Flange (item no.5) to the turning table (item no.2),
and tighten or loosen the M12-12 setscrew (item no.20) by making use of an allen wrench through
the openings on the fork until you maintain the desired angular accuracy, once you get this
accuracy, tighten M12 screw again.
2. Decrease in the cutting capacity
Cause: The saw blade gets dull.
Measure: Sharpen the saw blade.
3. The revolving action of table was loosen.
Cause: The locking mechanism below the revolving table may not be clean.
Measure: Please dismount and clean the mechanism.Keep the mechanism continously clean for
proper cutting.
4. Machine is not working.
Cause: Main power supply line is off.
Measure: Check the power cable, switch, power socket (earthed socket) and power mains.
5. Machine is not working.
Cause: Main power is on but electric motor is not running.