Set Same Unit; Set Visible Light Parameters - HIKVISION HM-TD5567T-7/W User Manual

Thermal & optical bi-spectrum ptz network camera
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
between the device and the computer or terminal when the communication distance is too long.
Before You Start
Connect the device and computer or terminal with RS-485 cable.
Steps
1. Go to Configuration → System → System Settings → RS-485.
2. Set the RS-485 parameters.
Note
You should keep the parameters of the device and the computer or terminal the same.
3. Click Save.
Note
The settings take effect only for the PTZ channel.

14.13 Set Same Unit

Set the same temperature unit and distance unit. When you enable this function, the unit cannot
be configured separately in other setting pages
Steps
1. Go to Configuration → System → System Settings → Unit Settings.
2. Check Use Same Unit.
3. Set the temperature unit and distance unit.
4. Click Save.

14.14 Set Visible Light Parameters

When the FOVs (Field of View) of the optical channel and thermal channel are not the same,
adjust the visible light optical axis to make sure the FOVs in the two channels are the same.
Steps
1. Go to Configuration → System → Maintenance → System Service.
2. Select Visible Light Optical Axis Adjustment from the drop-down list.
3. Check Enable Visible Light Optical Axis Adjustment.
4. Adjust the optical zoom ratio to the maximum value via PTZ control panel.
5. Click the direction buttons to adjust the position of the visible light optical axis.
6. Adjust the sensitivity. The higher the value is , the faster the cursor moves.
7. Click Save when the FOVs of the optical channel and thermal channel are the same.