Page 1
WITH MOSQUITO CATCHER OPERATION MANUAL “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. * The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm which is measured around the center of a room applicable fl...
Page 18
Please read before operating your new Air Purifi er The air purifi er draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the main unit, and then discharges it through the air outlet.
Page 19
Cleanliness Monitor light off and the UV Light less bright, while mosquito catcher function is still on. Thank you for purchasing the SHARP Air Purifi er. Please read this manual carefully. Before using this product, be sure to read the section: “Important Safety Instructions.”...
If the air purifi er interferes with radio or replaced by the manufacturer, its service television reception, try one or more of the agent, a Sharp authorized Service following measures: Center or similarly qualifi ed persons in order to avoid a hazard. Contact the •...
Page 21
CAUTIONS CONCERNING INSTALLATION GUIDELINES OPERATION • Avoid locations where the sensors are exposed to direct wind. • Do not block the air intake or air outlet. Doing so can cause the main unit to • Always operate the main unit in an upright malfunction.
PART NAMES FRONT Cleanliness Monitor Blue Clean Indicates the air purity of the room in 3 levels with color changes. Orange Impure Main Unit Air Outlet OFF TIMER Button, Light (white) (Press 3 sec.) Filter Reset Button, REPLACE FILTER Light (orange) MODE Button, Light (white) (Press 3 sec.) Plasmacluster Ion ON/OFF Button CLEAN ION SHOWER Button, Light (white)
Page 23
BACK Hold this Handle when lift- (INSIDE) ing the main unit. INCLUDED • Glue Sheet : 3pieces UV Light Dust sensor / Dust sensor Filter HEPA Filter Deodorizing Filter Pre-Filter Catch Panel Air Inlet Handles Magnet Upper Hooks Bottom Hooks Power Cord Power Plug (Shape of plug depends on country.) Glue Sheet...
FILTER AND GLUE SHEET INSTALLATION To maintain the quality of the fi lter and Glue Sheet, it is installed in the main unit and packed in plastic bag. Be sure to remove the fi lter and Glue Sheet from the plastic bag before using the main unit.
Page 25
Be sure to remove the power plug from the wall outlet. Remove the protective fi lm slowly Remove the Glue Sheet from the plastic bag. from the corner of Glue Sheet. ・Dispose protective fi lm as ・Keep the additional Glue Sheet burnable rubbish.
OPERATION START / STOP START STOP • When the main unit starts operation, the operation starts in the previous mode it was operated in. CLEAN ION SHOWER The main unit releases Plasmacluster ions with strong airfl ow and collects dusts while decreasing static electricity for 10 minutes.
Page 27
MOSQUITO CATCHER Use this function when there is concern about mosquitoes. UV Light ON UV Light OFF NOTE • When SHEET RESET Light is turned on, please replace the Glue Sheet with a new one. • Select MAX mode to catch mosquito more effectively. The higher the air volume is, the easier it is to capture a mosquito.
OPERATION CARE AND MAINTENANCE To maintain optimum performance of this air LIGHT CONTROL purifi er, please clean the main unit including the fi lter periodically. You can set the Cleanliness Monitor / Be sure to disconnect the power cord from Plasmacluster Ion Light to OFF when their SIGN is the wall outlet before performing any mainte- bright.
Page 29
Be sure to remove the power plug from the wall outlet. FILTERS Gently remove dust from HEPA Filter and Deodorizing Filter with a HEPA Filter vacuum cleaner attachment or similar tool. CAUTION Do not WASH in water and DRY in the sun. The fi...
REPLACEMENT FILTERS Model : FZ-F50HFE HEPA Filter Replacement timing When REPLACE FILTER Light turn on.* Deodorizing Filter Model : FZ-F50DFE *The REPLACE FILTER Light will turn on after approximately 17,500 hours in sleep mode. ( 2 years × 24 hours = 17,500) Filter life varies depend on the operation mode.
Page 31
Be sure to remove the power plug from the wall outlet. GLUE SHEET Replacement timing When SHEET RESET Light turn on. Model : FZ-STS2M Replace the Glue Sheet according to the operation manual included in the replacement Glue Sheet. Please discard the used Glue Sheet carefully. Do not touch the adhesive surface.
TROUBLESHOOTING Before calling for service, please review the Troubleshooting chart below, since the problem may not be the main unit malfunction. SYMPTOM REMEDY (not a malfunction) Odors and smoke are not removed. • Is fi lter still in the plastic bag? Please take it out. (Page 6) •...
When the adhesive remains on • Wipe with cooking oil, then wash with soap and water. clothes, skin, fl oor, etc. MOSQUITO CATCHER Light is • UV Light has failed. Please call the service center approved by Sharp. fl ashing. SPECIFICATIONS Power supply...
Need help?
Do you have a question about the FP-JM40B and is the answer not in the manual?