Programming Mode - Collect Mode - LG RN1870AH1 Owner's Manual

Commercial dryer
Table of Contents

Advertisement

Available languages

Available languages

PROGRAMMING MODE - Collect Mode

Collect Information Data : CLCt (display)
The dryer collects the usage data so that the owner can check various information like number of various cycles
used, how many times card or coins used, etc.
Entering the collect mode
Data Name
Step (Button)
1. Entering the
programming mode.
2. High Temp.
Entering
3. Med Temp.(+) or Low
the collect
Temp.(-)
mode
4. Start
5. Med Temp.(+) or Low
Temp.(-)
6. Start
Check the collect information reference to the follow lists. The Lists are displayed by abbreviations.
Collect Mode Data lists
No.
Abbreviation
1
rgPr
2
rgCP
3
rgrP
4
rgHP
5
dELC
6
ItrC
7
ItCC
8
ItAC
9
ItHC
10
ItSC
11
IttF
12
ItUC
13
ItFC
14
ACrC
15
ACCC
16
ACAC
17
ACHC
18
ACSC
19
ACtF
20
ACUC
21
ACFC
22
ACrt
LED Display
Meaning
Regular Price
Regular Cold Price
Regular Warm Price
Regular Hot Price
Dryer Moisture Sense
Interval Regular Cycles
Interval Regular Cold Cycles
Interval Regular Warm Cycles
Interval Regular Hot Cycles
Interval Super Cycles
Interval Topoff Cycles (Dryer Only)
Interval Service Cycles
Interval Token Cycles
Accumulated Regular Cycles
Accumulated Regular Cold Cycles
Accumulated Regular Warm Cycles
Accumulated Regular Hot Cycles
Accumulated Super Cycles (Washer Only)
Accumulated Topoff Cycles (Dryer Only)
Accumulated Service Cycles
Accumulated Token Cycles
Accumulated Run Time
Description
Insert service card(Card type), Turn on/off toggle switch
(Coin type).
Press the High Temp. button until "tESt" appears in the
display.
Press the Med Temp. or Low Temp. button until "CLCt"
appears in the display.
Enter the Collect information data.
Move to each data list that you want to check by pressing
with Med Temp. or Low Temp. button.
Display the value of selected data list
500~9500
rgCP is not available in dryer. (It can't enter.)
rgrP is not available in dryer. (It can't enter.)
rgHP is not available in dryer. (It can't enter.)
dELC is not available in dryer. (It can't enter.)
Number of Regular cycles (0 ~ 65535)
ItCC is not available in dryer. (It can't enter.)
ItAC is not available in dryer. (It can't enter.)
ItHC is not available in dryer. (It can't enter.)
ItSC is not available in dryer. (It can't enter.)
Number of Topoff cycles (0 ~ 65535)
Number of Service cycles (0 ~ 65535)
Number of Token cycles (0 ~ 65535)
Number of Regular cycles (0 ~ 65535)
ACCC is not available in dryer. (It can't enter.)
ACAC is not available in dryer. (It can't enter.)
ACHC is not available in dryer. (It can't enter.)
ACSC is not available in dryer. (It can't enter.)
Number of Topoff cycles (0 ~ 65535)
Number of Service cycles (0 ~ 65535)
Number of Token cycles (0 ~ 65535)
Number of Running minutes (0 ~ 65535)