Design Notice

In order to ensure the optimal performance of our products, the design speci cations of the unit and
remote control are subject to change without prior notice.

Ambient Temperature Range For Unit Operating

MODE
Temperature Range
Cool
17-35°C (62-95°F)
Dry
13-35°C (55-95°F)

Exhaust Hose Installation

The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For
COOL,HEAT(heat pump type) or AUTO mode must be installed exhaust hose. For FAN, DRY or HEAT
(electrical heat type) mode must be removed exhaust hose.

Choosing The Right Location

Recommend Installation
Page 12
control panel
remote signal receptor
horizontal louver control
lever(adjust manually)
NOTE: PHA can not be
adjusted.
vertical louver control
lever(adjust manually)
NOTE: PHA can not be
adjusted.
panel
Caster
MODE
Heat(pump heat mode)
Heat(electrical heat mode)
Your installation location should meet the following requirements:
-Make sure that you install your unit on an even surface to minimize noise and
vibration.
-The unit must be installed near a grounded plug, and the Collection Tray Drain
(found on the back of the unit) must be accessible.
-The unit should be located at least 50cm (19.7") from the nearest wall to ensure
proper air conditioning. The horizontal louver blade should be at least 50cm
(19.7") away from obstacles.
-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this
could cause damage to the unit.
handle
(both sides)
air filter
upper air intake
drain outlet
air outlet
lower air intake
bottom tray
drain outlet
rear
Temperature Range
5-30°C (41-86°F)
30°C (86°F)