recovery occurs. The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall
be complete with leak-free disconnect couplings and in good condition. Before using the recovery
machine, check that it is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier
in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants
in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed,
为增强通用性,已
删除原说明书中的
ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant
机型外观轮廓图,
does not remain within the lubricant. The evacuation process shall be carried out prior to returning the
保留的轮廓图只用
compressor to the suppliers. Only electric heating to the compressor body shall be employed to
于示例说明。以用
户实际购买产品为
accelerate this process. When oil is drained from a system, it shall be carried out safely.
准。

Installation Instructions

Preparation

CThe unit can be controlled by the unit control panel alone or with the remote
controller. This manual does not include Remote Controller Operations, see the <<Remote Controller
Instruction>> packed with the unit for details.

Design Notice

In order to ensure the optimal performance of our products, the design specifications of the unit
and remote control are subject to change without prior notice.

Ambient Temperature Range For Unit Operating

MODE
Temperature Range
Cool
17-35°C (62-95°F)
Dry
13-35°C (55-95°F)
control panel
horizontal louver
blade
Caster
front
upper air filter
handle
(both sides)
upper air intake
drain outlet
air outlet
lower air filter
lower air intake
power plug socket
drain outlet
(only for pump
heating mode)
power cord outlet
power cord buckle
bottom tray
drain outlet
MODE
Temperature Range
Heat(pump heat
5-30°C (41-86°F)
mode)
Heat(electrical
30°C (86°F)
heat mode)
rear
Page 11