Model: ROG14KMCDN
Fan speed is defined by outdoor temperature and compressor frequency.
• Outside air temperature zone selection
Fan step
S-HIGH2
S-HIGH1
HIGH
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,200 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
Cooling
Heating
Y zone
—
1,200
1,180
1,200
1,180
1,200
—
1,170
1,180
1,170
1,140
1,000
900
860
800
750
690
700
610
610
550
570
450
510
400
470
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
Dry
Cooling or dry at low outdoor temp.
Y zone
Z zone
—
—
—
—
—
—
—
—
1,180
1,180
1,140
600
900
600
800
450
690
320
610
320
550
320
450
320
400
320
- (04-15) -
19°C
10°C
0°C
Unit: rpm
F zone
G zone
—
—
—
—
1,180
310
310
260
230
230
230
230
230
—
—
—
—
1,180
220
220
200
180
180
180
180
180
3. Fan control