Download Print this page

Optex InSight Series Installation Instructions page 3

Visual verification pir camera

Advertisement

4-2. Vertical adjustings
PIR area adjustment
1
Vertical: 0° to -20°
Caution
Do not use the vertical angle adjustment of the main unit other than adjusting
the detection area surface to be parallel to the ground inclination.
Parallel
4-3. PIR/VCA settings
Refer to the InSight VCA manual for details on Camera angle and
PIR area settings.
InSight VCA manual
https://navi.optex.net/manual/50426/en/?type=VCAmanual
4-4. Detection range limit
The default settings are 18 m (60') at 2.5 m (8'2") mounting height.
If no changes are required, proceed to the next item.
INS-HX-80N Full manual
https://navi.optex.net/manual/50427/en/?type=installationinstructions
4-6. Put on the back cover
2
Adjust the detection range
Step
5
Checking
Walk test: Check the detection area by walking around the area.
1
System check: Check the image at the time of detection on the monitoring portal.
Camera angle adjustment
2
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw.
NOTE
It is recommended that use the Camera angle at 25° to 35°
since camera images may appear white and blurred in dark scenes.
Caution
If the vertical angle of the camera is to be adjusted, adjustment of this
sections must be matched to ensure the best performance of the sensor.
4-5. Switch settings
Change DIP switch settings as needed
1
OFF
ON
OFF
ON
Standard
Immunity
Immunity
Future use
PIR Logic
AND
OR
Change PIR sensitivity setting as needed
2
High
Middle
Low
3
20°min.
Default
30°
35°max.
LED
Default
H
M
L
Default

Advertisement

loading

This manual is also suitable for:

Insight ins-hx-80n