Set the gas cooker knob to the small flame setting.
2.
Check whether the flame safety system is working
by keeping the flame at the "small flame" setting for
1 minute.
3.
Check that the burners are burning correctly with
both large and small flames.
a The flame must burn evenly and steadily.
Turn the burner knob back and forth quickly
4.
between the large flame setting and the small flame
setting. Repeat this process several times.
a The gas flame must not flicker or go out.
22.8 Technical data – Gas
The different types of gas and the corresponding values are listed.
Technical data – Gas
Note the following information for the gas types that are listed in the table for some burners.
Natural gas NG G20/2.0 kPa
Nozzle (mm)
Bypass
1.16
0.78
0.97
0.60
0.72
0.52
1.48
0.94
1.48/0.70
0.92/0.57
1.47
0.76
1.30
-
Liquid gas, butane, propane, G30/mb2.8-3.0 kPa
Nozzle (mm)
Bypass
0.85
0.49
0.65
0.40
0.50
0.32
1.00
0.59
0.95/0.44
0.57/0.30
0.90
0.56
0.85
-
Liquid gas, butane, propane, G30/5.0 kPa
Nozzle (mm)
Bypass
0.75
0.49
0.58
0.40
0.43
0.32
Burner type
High-output burner
Standard-output burner
Economy burner
Wok burner
Dual-flame wok burner
Oven burner
Grill burner
Burner type
High-output burner
Standard-output burner
Economy burner
Wok burner
Dual-flame wok burner
Oven burner
Grill burner
Burner type
High-output burner
Standard-output burner
Economy burner
Checking the correct burner behaviour for the
lower oven gas burner
Ignite the lower oven gas burner in accordance with
1.
the instructions in the operating manual.
→ "Basic operation", Page 19
Open the oven door and observe the flame.
2.
a The flame must burn evenly.
a The flame may fail during the first few minutes. How-
ever, the flame must stabilise after a few minutes.
Switch on the appliance for a few minutes to check
3.
whether the thermocouple becomes sufficiently
warm.
a Adjust the settings, if required. If the bypass nozzle
on the burner is faulty, replace this.
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
4.0
≤ 1.7
4.2
≤ 2.6
4.2
-
3.1
-
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
4.0
≤ 1.7
4.2
≤ 2.6
4.2
-
3.1
-
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
Installation instructions en
Max. consump-
tion
3
G20  (m
/h)
3
0.285  (m
/h)
3
0.167  (m
/h)
3
0.095  (m
/h)
3
0.381  (m
/h)
3
0.399  (m
/h)
3
0.399  (m
/h)
3
0.295  (m
/h)
Max. consump-
tion
G30  (g/h)
218  (g/h)
127  (g/h)
73  (g/h)
291  (g/h)
306  (g/h)
306  (g/h)
226  (g/h)
Max. consump-
tion
G30  (g/h)
218  (g/h)
127  (g/h)
73  (g/h)
43