Bosch HGW3FSY50Z User Manual And Installation Instructions page 39

Free standing cooker
Hide thumbs Also See for HGW3FSY50Z:
Table of Contents

Advertisement

¡ Enter the newly set type of gas and gas pressure in
the table. You can find additional information about
this in the section entitled "Appliance information"
→ Page 37.
ATTENTION!
After converting the type of gas, label the type of gas
that is now set.
After converting the type of gas, affix the label with
the specification of the gas type and the star shape
at the designated location on the appliance's rating
plate.
Parts for the gas conversion
The parts that you need for the gas conversion proced-
ure described here are listed below.
Note:
The accessories supplied may differ depending on the
appliance model.
¡ The gas connecting piece may vary depending on
the gas type and the country-specific regulations.
¡ To determine the correct nozzle diameter, check the
→ "Technical data – Gas", Page 43 table.
¡ Always use a new seal.
¡ (*) Never establish a gas connection without these
parts.
Explanation
Bypass nozzle
Burner nozzle
(*) Seal
(*) Connecting piece for nat-
ural gas (NG: G20, G25)
¡ TS 61-210 EN 10226 R½
¡ EN 10226 R½
(*) Connecting piece for nat-
ural gas (NG: G20, G25)
¡ TS EN ISO 228 G½
¡ EN ISO 228 G½
(*) Connecting piece for liquid
gas (LPG: G30, G31)
Connecting piece
Blind plugs (closure part)
Replacing the cooker burner nozzles
Switch off all of the knobs on the control panel.
1.
Close the gas connection shut-off.
2.
Remove the pan support grids or the pan support
3.
racks and the burner parts.
Use the socket wrench 7 to remove the cooker
4.
burner nozzles.
If your appliance features a wok burner with side ac-
5.
cess, remove the burner nozzle as shown below.
7
Look up the burner nozzles in the table. You can
6.
find additional information about this in the section
entitled
→ "Technical data – Gas", Page 43.
Fit the new nozzles into the appropriate burners.
After replacing the nozzles, check that there are no
7.
leaks. You can find additional information about this
in the section entitled "Leak and function test"
→ Page 42.
Adjusting or replacing bypass nozzles (small
flame setting)
You can set the minimum flame height for the burners
via the bypass nozzles.
Requirements
¡ Close the gas isolating equipment.
¡ Disconnect the appliance from the power supply.
Switch off all of the knobs on the control panel.
1.
Installation instructions en
7
39