Advertisement

Quick Links

UV LIGHT METER
532
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for Perfect Prime 532

  • Page 1 UV LIGHT METER Instruction Manual...
  • Page 2: Table Of Contents

    CONTENTS 1. Safety Information ..............2 2. Introduction ................. 3 ............4 3. Precautions On Handling 4. Maintenance ................. 4 5. Specifications ............... 5 6. Symbol Definition And Button Location 6.1 LCD Display ..............6 6.2 Name Of Parts & Position ..........
  • Page 3: Safety Information

    1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as speci ed in this manual ; otherwise, the protection provided by the meter may be impaired. ENVIRONMENT CONDITIONS: Altitude up to 2000 meters •...
  • Page 4: Introduction

    2. INTRODUCTION Thank you for using our UV Light Meter. To ensure that you can get the most from it, we recommend that you read and follow the manual carefully before use. The UV Meter has been designed, manufactured, and delivered under strict quality control criteria.
  • Page 5: Precautions On Handling

    3. PRECAUTIONS ON HANDLING 4. MAINTENANCE 3. PRECAUTIONS ON HANDLINGE Operating carefully, and do not drop the meter or hit it with a hard object. Avoid using the meter in a dirty, dusty, or salt-air area or where there are corrosive gases.
  • Page 6: Specifications

    5. SPECIFICATIONS Low range: 1 to 3999 uw/cm2 Measuring range: High range: 0.01 to 39.99 mw/cm2 260 nm ~ 395 nm Sensitivity Wavelength Region (nm): 365 nm Wavelength for Calibration (nm): ±3% rdg ±5 dgts Accuracy: ±0.1% / °C(away from 25°C) Temperature characteristics: 0.5 sec Response time:...
  • Page 7: Symbol Definition And Button Location

    6. SYMBOL DEFINITION AND BUTTON LOCATION 6.1 LCD Display: Minimum value indicator Maximum value Autopower indicator o indicator Value hold indicator Battery capacity indicator Ultraviolet intensity value indicator Ultraviolet intensity Unit indicator...
  • Page 8: Name Of Parts & Position

    6. SYMBOL DEFINITION AND BUTTON LOCATION 6.2 Name of Parts & Position 1 Light Sensing Probe: This probe can be xed on the meter parallel or perpendicular to the • LCD surface.
  • Page 9 6. SYMBOL DEFINITION AND BUTTON LOCATION Or it may be detached from the • unit to t the measuring requirement. LCD display: 6 1/2" large size back light LCD display.
  • Page 10 6. SYMBOL DEFINITION AND BUTTON LOCATION Power button: Push this button to turn on the meter. Push and hold this button for 3 seconds to turn it o . The unit will automatically turn itself o after 30 minutes if there is no key operation. To disable the automatic power o function, turn the meter o , push and keep holding “...
  • Page 11 6. SYMBOL DEFINITION AND BUTTON LOCATION uw/cm selector button: To switch the measuring range to lower range with unit uw/cm mw/cm selector button: To switch the measuring range to higher range with unit mw/cm Battery cabinet cover: When battery capacity segment is less than one, the user should replace the battery.
  • Page 12: Characteristics Of Sensor Spectrum Response

    7. CHARACTERISTICS OF SENSOR SPECTRUM RESPONSE Wavelength (nm)(%) P.11...
  • Page 13 CUSTOMER SERVICE INQUIRIES Your emails are important to us so we strive to reply all hours. In exceptional cases, inquiries and emails within we may require more time to respond. Thank you for your understanding. For more information about our products and services, please send us an email: cs@perfectprime.com For B2B or project-based application, please send an email:...
  • Page 14 Tyche Smart Limited Retailer Email cs@perfectprime.com 2nd Floor, 107 Charterhouse Street, EC1M 6HW, London, Address England UNITED KINGDOM +44 203 7695377 Telephone...

Table of Contents