  • Page 1 Digital Pressure Gauge AR168 Instruction Manual...
  • Page 2: Table Of Contents

    CONTENTS 1. PRODUCT INTRODUCTION ........2 2. BASIC FUNCTIONS ........... 2 3. TECHNICAL PERFORMANCE ........3 4. RANGE OF PRESSURE MEASUREMENT ......4 5. SYMBOL DEFINITION & BUTTON LOCATION ... 5 - 6 6. KEY OPERATION ..........7 - 8 7.PRECAUTIONS ............
  • Page 3: Product Introduction

    1. PRODUCT INTRODUCTION 2. BASIC FUNCTIONS PRODUCT INTRODUCTION The AR168 is a professional high precision, high range, high resolution digital pressure gauge for indoor temperature measurement with a large screen display. It measures the pre-blue detection pressure value relative to the current atmospheric pressure. The dual channel can simultaneously detect the pressure di erence between two detection ports.
  • Page 4: Technical Performance

    3. TECHNICAL PERFORMANCE Measuring Range ±2.999 Psi Unit of measurement Psi, kg/cm2, ozin2, bar, mbar, Pa, kPa, inHg, mmHg, inH2O, ftH2O, cmH2O Accuracy ±0.3% FSO (25°C) Repeatability ±0.2% (MAX ±0.5% FSO) Linearity/Hystersis ±0.29% FSO (25°C) Measurement rate 0.5s Data Storage 100 groups Maximum withstand pressure 50KPa...
  • Page 5: Range Of Pressure Measurement

    4. RANGE OF PRESSURE MEASUREMENT Unit Range Resolution ±20.68 0.001 ±2.999 0.001 kgcm² ±0.210 0.001 ozin² ±47.99 0.01 ±0.206 0.001 mbar ±206.8 inHg ±6.106 0.001 mmHg ±151.1 inH2O ±83.02 0.01 ftH2O ±6.918 0.001 cmH2O ±210.8 ±9999...
  • Page 6: Symbol Definition & Button Location

    5. SYMBOL DEFINITION & BUTTON LOCATION Temperature Display Di erential Pressure Mode Low Power Symbol Reading display Hold Function Pressure Units Max/Min Reading...
  • Page 7 5. SYMBOL DEFINITION & BUTTON LOCATION HOLD UNITS ºC/ºF Power on/o Button LCD Display °C/°F Button Tube Connector(+) HOLD Button Tube Connector(-) UNITS Button Label position DIF Button Hanging Hole MAX Button Battery Cover...
  • Page 8: Key Operation

    6. KEY OPERATION 1. Power on/off Button When power is o : short press to turn device on. When power is on: a. Press this button to open/close backlight. b. Press this button over 2 seconds to turn o the meter. c.
  • Page 9 6. KEY OPERATION 6. MAX Button a. Short press to view stored data b. Press and hold for 2 seconds to enter the maximum and minimum mode c. Press and hold for more than 2 seconds to return to the normal measurement mode...
  • Page 10: Precautions

    7.PRECAUTIONS When the meter is working, keep it away from vibration sources and strong electromagnetic elds, and environmental locations with drastic temperature changes, so as not to be interfered and cause inaccurate measurement data. When measuring corrosive and toxic gases or liquids, please take precautionary measures to avoid danger or damage to the instrument Please replace the battery in time when the meter shows a low...
  • Page 11 CUSTOMER SERVICE INQUIRIES Your emails are important to us so we strive to reply all hours. In exceptional cases, inquiries and emails within we may require more time to respond. Thank you for your understanding. For more information about our products and services, please send us an email: cs@perfectprime.com For B2B or project-based application, please send an email:...
  • Page 12 HORMES LIMITED Retailer cs@perfectprime.com Email G/F UNIT 3, 61 GLENTHORNE ROAD, Address LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Telephone...