1. INTRODUCTION/ 2. SPECIFICATIONS INTRODUCTION The TC0304 is a 4 channel digital thermometer for use with any K-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC584 temperature/voltage table for K-type thermocouples. It uses RS232 interface to perform bi-directional communication with PC.
3. SYMBOL DEFINITION AND BUTTON LOCATION : This indicates that the minus temperature is sensed. °C °F : Centigrade and Fahrenheit indication. : Thermocouple Type Indication. : The Maximum value is now being displayed. : The Minimum value is now being displayed. : This indicates auto power o is enabled.
Page 7
3. SYMBOL DEFINITION AND BUTTON LOCATION T1-T2 HOLD 9V BATTERY NEDA 1604 6F22 006P PLEASE READ MANUAL FOR SAFETY RANGE 200 C 1370 C 2498 OPEN POWER-UP OPTIONS K type temperature sensor T1 °C, °F control button to T4 input connector O set calibration screw LCD display Digital output connector...
4. OPERATION INSTRUCTIONS 4.1 POWER UP & TURN ON/OFF BACKLIGHT key turns the Thermometer ON or OFF and backlight ON & OFF. Press it once to turn on the Thermometer. Press it again for moment to turn ON or OFF backlight. Press and hold this button 3 second to turn OFF the power.
4. OPERATION INSTRUCTIONS 4.5 T1 T2 OPERATION When this button is pushed, “1 – 2 ” will be shown on the upper right hand side LCD display to indicate that the tester is under T1 minus T2 mode. The temperature di erence is shown on the right hand side display as shown in Fig.
4. OPERATION INSTRUCTIONS One may press "MAX MIN" to circulate the display mode among these options. When the meter is under "MAX MIN" operation and “ °C/°F ”, “▲REL” button are disabled.(when you press “ °C/°F ”, “▲REL” button in "MAX MIN"...
4. OPERATION INSTRUCTIONS 4.10 CALIBRATION POINT input Adjust VR Tolerance 0 °C ± 0.1 °C 190 °C ± 0.1 °C 1000 °C ± 1 °C 1900 °F ± 1 °F P.S Normally, performing o set Calibration with thermal stabled ice water through VR1 will give a very good calibration result.
4. OPERATION INSTRUCTIONS APPENDIX: THERMOCOUPLE PROBE SPECIFICATION Model Range Tolerances Description with Te on TP-K01 -50°C, to 200°C, ±2.2°C or ±0.75% tape insulation Bead probe Maximum -58°F to 392°F (±3.6°C or ±0.75%) insulating temperature : 260°C TP K01: probe for general condition measurements, especially for complex and hard to reach places.
5. SETUP SOFTWARE OPERATING SYSTEM REQUIRED: WINDOWS XP/ VISTA/ WINDOWS 7/ WINDOWS 8/ WINDOWS 10 MINIMUM HARDWARE REQUIRED: • At least 50 MB hard disk space available to install the software • Download software here: https://perfectprime.com/pages/manual, locate your product under Thermocouple Thermometer and download the software TUTORIAL QUICK START TO USE SOFTWARE: •...
Page 14
CUSTOMER SERVICE INQUIRIES Your emails are important to us so we strive to reply all hours. In exceptional cases, inquiries and emails within we may require more time to respond. Thank you for your understanding. For more information about our products and services, please send us an email: cs@perfectprime.com For B2B or project-based application, please send an email:...