Assigning temperature zones
Setpoint adjusters or room temperature sensors which are
used are already assigned (fixed) via their wiring.
Example: Assigning room name LIVING to zone 1
Press the configuration button (1) on the storey controller.
Assignment of the storey controller to the central operating device
is displayed. The green LED illuminates if a temperature zone is
already assigned to the central operating device. The red LED
illuminates if a setpoint adjuster or room temperature sensor is
connected.
If temperature zone 1 is already assigned to the central
operating device, the existing assignment is overwritten by a
new assignment.
Press the configuration button (1) on the storey controller twice.
The green LED of the first zone flashes. The storey controller waits
for a signal from the central operating device.