Conditions And Recovery Steps; Bezel Led Error Flash Codes And Recovery Steps - CPI TALOS T6 Installation Manual

Hide thumbs Also See for TALOS T6:
Table of Contents

Advertisement

This chapter outlines:
• Note validator conditions and recovery steps

Bezel LED error flash codes and recovery steps

Condition
Note validator does not power up
Note validator has power, but it does not accept a note
When the unit is ready and enabled, bezel LEDs continuously flash.
If the bezel LEDs are off, the unit has an error.
To determine the error:
Partially insert and hold a note in the note path
Count the bezel light flashes.
Refer to the chart below for conditions and recovery steps.
No. of Flashes
None
1 or 4
2
3
5
Continuous fast
Continuous slow
12
1
Condition
Recovery Steps
No power
Restore power to the note validator or host machine.
1. Check for jams.
Note path in the note
2. Remove the note magazine and lower housing assembly from the note validator and
validator is blocked
1. Ensure the note validator is enabled.
2. Then check:
There is an issue with
another vending
component
1. Check that the lower housing assembly in the note validator is seated.
Lower housing assembly
2. Ensure the note path in the note validator is clean.
removed
Note magazine removed
from note validator
Reattach the note magazine in the note validator.
Note validator stacker is
full
Empty the note magazine in the note validator.
Note validator is defective
Replace the note validator.
Recovery Steps
1. Check harnesses.
– Cables may be loose or not properly connected.
– Pins may be bent.
2. Check the source voltage.
3. Ensure power is supplied to the note validator.
1. Check that the note validator is enabled.
2. Then check:
– The VMC.
– The coin manager and coin levels. Having low coin levels can cause the machine
to disable the note validator.
– Inventory levels.
– That the host machine door is properly locked.
until the bezel lights flash.
inspect.
– The VMC.
– The coin manager and coin levels.
– Inventory levels.
– That the host machine door is properly locked.
for more information.