SystemAir Fantech FIT 120E Series Installation And Operation Manual

SystemAir Fantech FIT 120E Series Installation And Operation Manual

Hide thumbs Also See for Fantech FIT 120E Series:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation and Operation Manual
Manuel d'installation et d'utilisation
FIT 120E Series
®
Fresh Air Appliance (FAA/ERV)
Appareil d'air frais (AAF/VRE)
PARTS IN THE BOX
Energy Recovery Ventilator, 1 pc
Ceiling bracket, 1 pc
Angle brackets, 2 pcs
External Damper Wire harness
(for FIT 120E only), 1 pc
Operation and Installation Manual, 1 pc
PIÈCES DANS LA BOÎTE
Ventilateur récupérateur d'énergie, 1 pc
Support muraux, 1 pc
Équerre d'assemblage, 2 pcs
Faisceau de câbles pour volet d'arrêt
mécanique
externe (FIT 120E seulement), 1 pc
Manuel d'installation, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
Votre système de ventilation doit être installé conformément aux exigences de la province où vous habitez ou, à défaut de
telles exigences, conformément à l'édition actuelle du Code national du bâtiment du Canada ou aux « méthodes d'ingénierie
appropriées » de l'ASHRAE.
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Fantech se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les
caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa
position de leader de technologie.
S'il vous plaît visitez notre site siteweb www.fantech.net pour des informations techiques plus détaillées.
Model: FIT 120E
Model: FIT 120E-D
Item #: 445657
Rev Date: 2023-02-09
No. d'article #: 445657
Date de révision: 2023-02-09
®
For FIT
120E-D-EC
only
Model: FIT 120E-D-EC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fantech FIT 120E Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SystemAir Fantech FIT 120E Series

  • Page 1 Item #: 445657 Installation and Operation Manual Rev Date: 2023-02-09 No. d'article #: 445657 Manuel d'installation et d'utilisation Date de révision: 2023-02-09 FIT 120E Series ® ® For FIT 120E-D-EC only Fresh Air Appliance (FAA/ERV) Appareil d'air frais (AAF/VRE) Model: FIT 120E PARTS IN THE BOX Energy Recovery Ventilator, 1 pc Ceiling bracket, 1 pc...
  • Page 2 Note Warning/ Information Technical Practical tip Important information note This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. This product meets ENERGY STAR requirements only when used in Canada. To ensure quiet operation of the ENERGY STAR certified H/ERV, each product model must be installed using sound attenua- tion techniques appropriate for the installation.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DETERMINING YOUR AIRFLOW REQUIREMENT ............4 INSTALLATION EXAMPLES Fully dedicated system .
  • Page 4: Determining Your Airflow Requirement

    DETERMINING YOUR AIRFLOW REQUIREMENT Room Count Method Room classification Number of rooms CFM (L/s) CFM Required Master bedroom x 10 L/s (20 CFM) if yes add 10 L/s (20 CFM) Basement yes or no if no = 0 Bedrooms x 5 L/s (10 CFM) Living room x 5 L/s (10 CFM) Others...
  • Page 5: Installation Examples

    Installation examples Suggested installation for: • Hydronic baseboard • Infloor heating • Electric baseboard • Mini split heat pump FULLY DEDICATED SYSTEM Benefits: Provides the best BEST FOR NEW CONSTRUCTION fresh air distribution in the Stale air is drawn from key areas of home (bathroom, kitchen, laundry) house;...
  • Page 6: Partially Dedicated System

    Installation examples (Cont'd) Suggested installation for: • Central furnace (air DIRECT CONNECTION of the FRESH air to living area to the RETURN PLENUM handling unit or central air of the AIR HANDLER (Stale air drawn from key areas of home) conditioners) •...
  • Page 7: Simplified Installation

    Installation examples (Cont'd) Suggested installation for: DIRECT CONNECTION of both the FAA SUPPLY AIR STREAM and EXHAUST AIR STREAM • When bathroom and kitchen to the FURNACE COLD AIR RETURN already have local exhaust system SIMPLIFIED INSTALLATION (GOOD) • May be suitable for (RETURN/RETURN METHOD) retrofitting •...
  • Page 8: Exterior Ducting Installation

    EXTERIOR DUCTING INSTALLATION WEATHERHOOD LOCATION OUTSIDE CORNER INSIDE CORNER • Decide where your intake and exhaust hoods will be located. 36" (1m) 36” (1m) min. min. Locating the Intake Weatherhood • Should be located upstream (if there are prevailing winds) from the 6' (2m) exhaust outlet.
  • Page 9: Interior Ducting Installation

    Interior ducting installation • To maximize airflow through the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. • 45º elbows are preferable to 90º. • Use “Y“ ducts instead of “T” ducts whenever possible. •...
  • Page 10: Faa Installation

    FAA installation LOCATION The FAA must be located in a conditioned space where it will be possible to conveniently service the unit. Typically the FAA would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted.
  • Page 11 Mounting CEILING INSTALLATION 1 Using the screw with washer mount the mounting bracket through the 2 Using the screw with washer mount the brackets at the bottom of the rubber insulator. Ensure the bracket is straight. unit. 3 Slide the unit the bracket as shown above. 4 Secure both side of the unit using the same method as step 1.
  • Page 12 Mounting WALL INSTALLATION 1 Using the screw with washer mount the mounting bracket through the 2 Using the screw with washer mount the brackets at the bottom of the rubber insulator. Ensure the bracket is straight. unit. 3 Slide the unit in the bracket and secure with setting screw.
  • Page 13: Airflow Adjustment & Balancing

    Airflow balancing Balancing must be completed using the Fantech Programmable Touch Screen Wall Control ENTERING BALANCING MODE In the options menu during the initial 5 second countdown sequence, long press on "ECO" area for 5 seconds to enter basic balancing mode. The supply and exhaust fans are adjusted on high speed only and the offsets are proportionally applied to the medium and low speed automatically.
  • Page 14: Wall Controls

    WALL CONTROLS * Please see instruction manuals for individual controls for proper wiring and set up of control systems. 1. Ensure that unit is not plugged when connecting the control 2. Recirculation mode is only available with the Flex100H ES, HERO series and the models with the “R” suffix at the end of the model number.
  • Page 15 WALL CONTROLS (CONT'D) EDF SERIES FEATURES CONNECTS TO • MODE button provides 3 modes of operations: VENTILATION, RECIRCULATION, and STANDBY mode. EDF8 • User selected fan speed: Reduced, Medium, Normal, and 20 minutes per hour. • AUTO setting allows the homeowner to deactivate the dehumidistat. •...
  • Page 16 Wiring diagram - FIT 120E & FIT 120E-D Observe polarity on all accessory controls where applicable.
  • Page 17 Wiring diagram - FIT 120E-D-EC Observe polarity on all accessory controls where applicable.
  • Page 18: Wiring Diagram

    Wiring diagram (CONT'D) WIRING DIAGRAM TO Standard Accessory Control Contact Standard Furnace Interlock Wiring FURNACE THERMOSTAT TERMINALS FOUR WIRE TWO WIRE heating only FOR A FURNACE CONNECTION TO A COOLING SYSTEM: On some newer furnaces and older FURNACE thermostats, energizing the R and 24-VOLT TERMINAL BLOCK G terminal at the furnace has the...
  • Page 19: Troubleshooting

    Troubleshooting Problem Causes Solutions Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from continuous mode to standby. FAA out of balance Have contractor balance FAA airflows Air is too humid Dehumidistat control is set too high Reduce the desired level of humidity.
  • Page 20: Faa Core Washing Instructions

    Filters and FAA core washing instructions For proper maintenance of your energy recovery core please follow these instructions To remove the door, loosen both latches on the bottom of the unit. Rotate the metal plate holding the FAA core in place. Remove both filters.
  • Page 21: Faa Maintenance Chart

    FAA maintenance chart Maintenance Required Recommended Frequency Date Maintenance Performed Check and Clean Filters Every 3 months or if dirty Check Energy Recovery Every 6 months Core Check Drain Pan and Every 3 months Lines Vacuum the Inside of the Annually Unit Clean and Un-block...
  • Page 22 No. d'article #: 445657 Date de révision: 2023-02-09 Manuel d'installation et d'utilisation 120E-D- 120E Serie EC seulement Appareil d'air frais (AAF/VRE) Modèl : FIT 120E PIÈCES DANS LA BOÎTE Modèl : FIT 120E-D Ventilateur récupérateur d'énergie, 1 pc Support muraux, 1 pc Équerre d'assemblage, 2 pcs Modèl : FIT 120E-D-EC...
  • Page 23 Note Avertissement/ Information Information Conseil Note importante technique pratique Ce produit a obtenu la certification ENERGY STAR® en respectant les directives strictes d'efficacité énergétique établies par Ressources naturelles Canada et l'EPA des ÉtatsUnis. Ce produit répond aux exigences ENERGY STAR uniquement lorsqu'il est utilisé...
  • Page 24 TABLE DES MATIÈRES DÉTERMINER VOS BESOINS DE VENTILATION ........... . . 26 EXEMPLES D'INSTALLATION Système entièrement spécialisé...
  • Page 25: Déterminer Vos Besoins De Ventilation

    DÉTERMINER VOS BESOINS DE VENTILATION Méthode compte de pièces Pi 3 /min (L/s) Liste des pièces Nombre de pièces PCM Required x 10 L/s (20 pi 3 /min) Chambre principale 3 /min Si oui, ajoutez 10 L/s (20 pi Sous-sol oui ou no Sinon = 0 x 5 L/s (10 pi 3 /min)
  • Page 26: Exemples D'installation

    Exemples d'installation Exemple seulement - La configuration des conduits peut être différente selon le modèle. Installation suggéré pour: • Plinthe à eau chaude • Chauffage de planché • Plinthe électriques • Thermopompe mural bibloc Avantages: Fourni la meilleure SYSTÈME ENTIÈREMENT SPÉCIALISÉ répartition de l’air frais dans (NOUVELLE CONSTRUCTION) la maison;...
  • Page 27: Système Partiellement Spécialisé

    Exemples d'installation (Suite) Installation suggérée pour: • Fournaise centrale (unité RACCORDEMENT DIRECT du FLUX D’AIR D’APPROVISIONNEMENT à la BOUCHE DE REPRISE de traitement d’air, air D’AIR DE LA FOURNAISE climatisé central) (L’air vicié est aspiré à partir des endroits clés de la maison.) •...
  • Page 28: Installation Simplifiée

    Exemples d'installation (Suite) Installation suggérée pour: RACCORDEMENT DIRECT du FLUX D’AIR D’APPROVISIONNEMENT et du FLUX D’AIR ÉVACUÉ • Lorsque la salle de bain DU AAF à la BOUCHE D’AIR DE LA FOURNAISE et la cuisine ont déjà un système d’échappement. INSTALLATION SIMPLIFIÉE (BONNE) •...
  • Page 29: Installation Des Conduits Extérieurs

    INSTALLATION DES CONDUITS EXTÉRIEURS EMPLACEMENT DES HOTTES Coin extéreur Coin intérieur OUTSIDE CORNER INSIDE CORNER • Décidez de l’emplacement des hottes d’aspiration et d’évacuation. 36po (1m) 36po (1m) 36" (1m) 36” (1m) min. min. Emplacement de la hotte d’aspiration • Doit être située en amont de la sortie d’évacuation (en présence de vents 3pi (900 mm) dominants).
  • Page 30: Installation Des Conduits Intérieurs

    Installation des conduits intérieurs • Pour maximiser le débit d’air dans le réseau de conduits, assurez-vous que tous les conduits sont le plus court et le plus droit possible. • Il est préférable d’utiliser des coudes de 45 degrés plutôt que des coudes de 90 degrés. •...
  • Page 31: Installation Du Aaf

    Installation du AAF EMPLACEMENT Le AAF doit être situé dans un endroit chauffé où il sera possible d’en effectuer l'entretient convenablement. Généralement, le AAF doit être situé dans la chambre des appareils mécaniques ou à proximité. S’il n’y a pas de sous-sol ou si le sous-sol ne convient pas, il est possible d’installer l’appareil dans la lingerie ou dans la buanderie.
  • Page 32: Installation Au Plafond

    Montage INSTALLATION AU PLAFOND 1 À l'aide de la vis avec rondelle, montez le support de montage à 2 À l'aide de la vis avec rondelle, montez les supports au bas de l'unité. travers l'isolant en caoutchouc. Assurez-vous que le support est droit. 3 Faites glisser l'unité...
  • Page 33: Installation Murale

    Montage INSTALLATION MURALE 1 À l'aide de la vis avec rondelle, montez le support de montage à 2 À l'aide de la vis avec rondelle, montez les supports au bas de l'unité. travers l'isolant en caoutchouc. Assurez-vous que le support est droit. 3 Faites glisser l'unité...
  • Page 34 ÉQUILIBRAGE L’équilibrage doit être réalisé à l’aide de la commande murale à écran tactile programmable Fantech. Ajustement des débits d'air ACCÉDER AU MODE D’ÉQUILIBRAGE Dans le menu d’options, lors de la séquence de décompte initiale de 5 secondes, appuyez sur la zone « ECO » pendant 5 secondes pour accéder au mode d’équilibrage de base.
  • Page 35: Commandes Murales

    COMMANDES MURALES * Veuillez consulter les manuels d’instructions des dispositifs de commande individuels pour connaître la bonne configuration de câblage et l’installation adéquate des systèmes de commande. 1. Assurez-vous que l’appareil n’est pas branché lorsque vous reliez la commande. 2. Le mode de recirculation n’est offert que sur les modèles Flex100H ES, Série HERO et les modèles dont le numéro de modèle comporte le suffixe « R »...
  • Page 36 COMMANDES MURALES (SUITE) SÉRIE EDF CARACTÉRISTIQUES RELIER À • BOUTON DE SÉLECTION offrant 3 modes de fonctionnement : ventilation, recirculation et attente. EDF8 • Vitesse du ventilateur sélectionnée par l’utilisateur : réduite, moyenne, ordinaire et 20 minutes par heure. • Mode AUTO permettant au propriétaire de désactiver le déshumidistat. •...
  • Page 37 Schémas électroniques - FIT 120E & FIT120E-D Respectez la polarité sur tous les accessoires de contrôles. Le cas échéant.
  • Page 38 Schémas électroniques - FIT 120E-D-EC Respectez la polarité sur tous les accessoires de contrôles. Le cas échéant.
  • Page 39: Schémas Électriques

    Schémas électroniques (SUITE) CONNEXION ÉLECTRIQUE Câblage standard de synchronisation avec une fournaise Standard Furnace Interlock Wiring À UNE FOURNAISE BORNES DU THERMOSTAT TERMINALS TERMINALS FOUR QUATRE FILS WIRE DEUX FILS TWO WIRE chauffage seulement heating only DANS LE CAS D'UNE FOURNAISE RACCORDÉE À...
  • Page 40: Dépannage

    Dépannage Problème Causes Solutions L’air est trop sec – Le déshumidistat est réglé trop bas – Augmentez le niveau voulu d’humidité. Faites passer le mode de ventilation de « continu » à « attente ». – Le AAF est déséquilibré –...
  • Page 41 Instructions de nettoyage des filtres et du noyau récupérateur d'énergie Pour un bon entretien de vos filtres et de votre noyau de récupération d'énergie suivez ces instructions Pour retirer la porte, desserrez les deux loquets situés à la partie inférieure de la centrale Faites pivoter...
  • Page 42: Tableau D'entretien Du Aaf

    Tableau d'entretien du AAF Entretien requis Fréquence recommandée Date de l'entretien Vérifiez et nettoyez les à chaque 3 mois, ou s'ils filtres sont sales Vérifiez le noyau récupé- À chaque 6 mois rateur d'énergie Vérifiez le bac de récu- À chaque 3 mois pération et les tuyaux d'échappement Nettoyez l'intérieur de...
  • Page 43 SERVICE MANUAL FIT 120E SERVICE MANUEL FIT 120E Description BOM # FIT 120E FIT 120E-D FIT 120E-D-EC La description Motor 448002 448002 448002 Electrostatic Filters 448004 448004 448004 Energy Recovery Cell 448005 448005 448005 Capacitors 450038 450038 PC board 428252 428252 428252 Auto-Transformer...
  • Page 44 Fantech reserves the right to make technical changes. Fantech se réserve le droit de faire des changements tech- For updated documentation please refer to www.fantech.net niques. Pour de la documentation à jour, s'il vous plaît se référer au www.fantech.net Fantech®...

This manual is also suitable for:

Fantech fit 120e-dFantech fit 120e-d-ec

Table of Contents