Pulsar PSACH 01244 Quick Start Manual

24vac/4a/1x4a ac power supply for 1 rotating camera, abs enclosure

Advertisement

Quick Links

PSACH 01244
v.1.2
PSACH 24VAC/4A/1x4A
AC power supply for 1 rotating camera, ABS enclosure
EN
Edition: 9 from 29.07.2022
Supersedes edition: 8 from 02.11.2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSACH 01244 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar PSACH 01244

  • Page 1 PSACH 01244 v.1.2 PSACH 24VAC/4A/1x4A AC power supply for 1 rotating camera, ABS enclosure Edition: 9 from 29.07.2022 Supersedes edition: 8 from 02.11.2017...
  • Page 2: Table Of Contents

    PSACH01244 Features:  ~24 V / 4 A or ~27 V / 3,7 A power output for  protections:  SCP short-circuit protection powering camera  power voltage ~ 230 V  OLP overload protection  OHP overheat protection ...
  • Page 3: Technical Description

    PSACH01244 1. Technical description. 1.1. General description. AC/AC PSU intended for supplying devices requiring voltage AC of ~24 V (U1= ~24 V / U2= ~27 V) and total capacity of 4 A@~24 V. It features protections: short-circuit (SCP), overload (OLP), transformer overheat (OHP).
  • Page 4: Specifications

    PSACH01244 1.4 Specifications: - electrical specifications (tab. 2) - mechanical specifications (tab. 3) - operation safety (tab. 4) - operating specifications (tab. 5) Electrical specifications (tab. 2). Supply voltage ~ 230 V Current consumption 0,5 A Power frequency 50 Hz Power of S PSU 100 VA max.
  • Page 5: Installation

    PSACH01244 Operating specifications (tab.5). Operating temperature -25ºC...+40ºC Storage temperature -25ºC...+60ºC Relative humidity 10%...90% without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN-83/T-42106 2. Installation. 2.1 Requirements AC/AC power supply is to be mounted by a qualified installer, holding relevant permits and licenses (required in installation country) to connect (interfere) with ~230 V mains supply.
  • Page 6: Operation And Use

    WEEE separately. Device works with a lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar sp. j. Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40 e-mail: biuro@pulsar.pl,...