Download Print this page

Hitachi P1 VFD Installation And Manual page 13

Advertisement

HB103
HB104
HB105
HB106
HB108
HB130
You can also modify the fan settings with this parameter.
Parameter
bA-70
Overspeed a Motor
If you want to command your spindle motor or grinding wheel to go faster than the base frequency,
command the spindle to go max RPM and use a tachometer to measure the speed. Then use the
following formula to calculate your new Max Output Frequency (Hb105):
Desired Max RPM * Current Max Frequency / Current Max RPM = New Max Frequency 
For example, if your Current Max Frequency is 60 and you measure the spindle runs 1030 RPM but
you actually want it to go 1515 RPM, calculate your new Max Frequency as follows: 
1515 * 60 / 1030=88 Hz. 
Make sure to recalibrate your RPM feedback and your spindle speed as both shown below. 
Calibrate Spindle Speed
Number Of Motor Poles 
Motor Base Frequency
Motor Max Output
Frequency
Motor Max Output Voltage
Motor Rated Current
Motor Min Output
Frequency 
Description
Cooling fan control
4 Poles
60 Hz
60 Hz
220 Volts
5 Amps
0.5 Hz
Default Value
0 (Always on)
2 to 12 Poles
1.0 to 590.0 Hz
1.0 to 590.0 Hz
1-510 Volts
 10% to 200% of drive
rated current
0.1 to 590.0 Hz
Desired Value
2 (Temperature controlled)

Advertisement

loading

This manual is also suitable for:

Wj200