Installation (continued)
LINE POWER should NOT be installed at this time. In the following steps electrical
components will be physically mounted. Ensure that all incoming power supplies have
been de-energized prior to beginning work on attachment of RapidSlat™ electrical control
systems. Use proper Lock Out/Tag Out procedures.
Do NOT connect components to electrical supply until directed to do so.
14. MOUNTING AND CONNECTING/WIRING STANDARD ELECTRICAL COMPONENTS
This step encompasses the installation and wiring of several components;
• Crank Handle Support Bracket and Switch,
• Junction Box,
• Control Panel,
• Photo Eye,
• Ballast Resistor, and
• Sensing Edge.
A. Install Crank Support Bracket and Interlock Switch. The top end of the hand crank will
mount onto the Crank Handle Support Bracket and be held vertically in place to the wall using
the provided clips and fasteners. The switch will be connected to the Junction Box in a later
step.
NOTE: Ensure the finished position of the Hand Crank hangs vertically above the floor and
where the crank handle will not interfere with anything.
1. Find a suitable location for mounting the Crank Handle Support Bracket, Hand Crank
Interlock Switch, and Hand Crank components that are near the motor and does NOT
interfere with the operation or installation of other components, Fig. 4–R.
2. Using appropriate fasteners and pre-drilled holes, mount the Crank Handle Support
Bracket to the wall.
3. Using appropriate fasteners, mount the Hand Crank Interlock Switch to the Crank Handle
Support Bracket.
4. Place hook end of Hand Crank onto the Support Bracket and verify hook rests on top of
and engages the Interlock Switch actuator. Make adjustments as required.
NOTE: Proper engagement of the Interlock Switch actuator is important!
5. Route the Interlock Switch cable from the switch to the future location of the Junction
Box. This cable will be connected after the Junction box is mounted.
6. Using appropriate fasteners, mount the Hand Crank to the wall.
7. Hang the Hand Crank on the Support Bracket.
www.overheaddoor.com
DANGER
608905-0007
Rev 7-03-2013
RapidSlat
Advanced Service Door
Junction
Box
Motor
Hand Crank
Interlock
Switch
Brake
Release
Cord
Bottom of Brake
Release Cord
Min 8 ft from floor
Hand Crank
Fig 4–R
16
Crank
Handle
Retainer