  • Page 1 Manual Maintenance Products: Enter Product Category / Model Number Installation Site Contractor Enter Project Name/Site info Enter Contractor Firm Name here Architect Distributor Overhead Door Company of ABC Enter Architect Firm Info Here 123 Eagle Street Eagle Town, TX 75067...
  • Page 2 • Elimination of non-budgeted maintenance cost for door service. As an Overhead Door distributor, we offer you complete product support for your service and maintenance needs. Do not hesitate to call us for assistance. We hope that you will also continue to consider for your future product and installation needs.
  • Page 3 Operation & Maintenance Manual Rolling Doors Table of Contents Section 1 General Information Section 2 Preventive Maintenance Section 3 Installation Instructions Section 4 Warranty ©Overhead Door Corporation Operation & Maintenance Manual: Rolling Doors...
  • Page 4 GENERAL INFORMATION ©Overhead Door Corporation Operation & Maintenance Manual: Rolling Doors...
  • Page 5 Overhead Door is the door solutions provider that delivers expert service and the highest level of performance and reliability. Our comprehensive product line encompasses a wide variety of commercial door solutions including: commercial operators, commercial sectional and rolling service doors, advanced performance rolling doors, and security grilles.
  • Page 6 PREVENTATIVE MAINTENANCE ©Overhead Door Corporation Operation & Maintenance Manual: Rolling Doors...
  • Page 7 Increase operational efficiency, safety and reliability  Extend useful life of your equipment  Reduce probability of equipment malfunctioning  Decrease costly downtime  Decrease long-term repair expense  Priority scheduling for service  Establish relationship with experienced, service-oriented professionals ©Overhead Door Corporation Preventative Maintenance...
  • Page 8 5. OPERATOR DOES NOT RUN. SOLUTION: a. Verify that electric power is available to the operator. b. Verify 24 VAC control voltage form operator transformer. c. Verify condition of hoist interlock switch. d. Verify condition of slidebolt interlock switch. ©Overhead Door Corporation Preventative Maintenance...
  • Page 9 The above frequency of maintenance is for normal operation. Severe duty or unusual operating conditions may require modification of the times between maintenance. A+B must equal more than ¼” Figure A Figure B ©Overhead Door Corporation Preventative Maintenance...
  • Page 10 22) Check that door is properly reset. 23) Test electric fusible links for continuity (where applicable). 24) Test smoke detector (where applicable). 25) Test hold-open devices and time delays (where applicable). 26) Inspect safety labels, placement and condition. ©Overhead Door Corporation Preventative Maintenance...
  • Page 11 INSTALLATION INSTRUCTIONS ©Overhead Door Corporation Operation & Maintenance Manual: Rolling Doors...
  • Page 12 Model 611 – Service Door 621 – Stormtite™ Door 626 – Stormtite™ Insulated Door Installation, repairs, and adjustments must be made by a trained door system technician using proper tools and instructions. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 13: Table Of Contents

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat Table of Contents ™ Advanced Service Door Section 1 ..................3-4 Section 5 (continued) • Safety Information ..................4 Photo Eye Adjustment ......................30 Control Wiring Low Voltage ....................31 • Safety Instructions ..................4 Rotary Transducer Wiring Connections/Settings ............32 Electrical Power Requirements ..................... 4 Reference: Conventional Wire Routing ................33 Section 2 ..................5-6 • Wiring Check List .
  • Page 14: Section 1

    Turn OFF electrical power before removing Control Panel or motor cover. When replacing Control Panel cover make sure wires are NOT pinched or near moving parts. Can Cause Serious Operator must be electrically grounded. Injury or Death ELECTRICAL SHOCK 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 15: Safety Information

    Over Current Protection device, but will cause the distributed capacitance in an ungrounded three phase system to shift. This shift may cause destructive over-voltages to occur). Overhead Door Corporation’s warranty WILL NOT cover damage caused by failure of the motor, control panel or other electrical components due to the use of an inadequately grounded system.
  • Page 16: Section 2

    Provides related information on service and maintenance items. • Section 10 - Illustrated Parts Breakdown Provides an illustrated parts breakdown for this product, including parts identification. • Section 11 - Return Goods Policy Provides returned goods policy information. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 17: Component Identification Drawing

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 Component Identification Drawing RapidSlat ™ Advanced Service Door DROP STOP DEVICE NON-DRIVE HEADPLATE BARREL ASSEMBLY DRIVE HEADPLATE NON-DRIVE END HOOD CURTAIN/BARREL FASTENERS DRIVE END HOOD INTERIOR HOOD GEAR BOX ROTARY TRANSDUCER MOTOR...
  • Page 18: General Information

    "G" DIMENSION__________ NAME PLATE SERIAL NUMBER: HEADROOM REQUIREMENT: NOTE: The ID plate is located on JOB NAME: SIDE ROOM: DRIVE__________ NON-DRIVE:__________ the bottom bar. GUIDE GAP __________ GUIDE TYPE___________ DISTRIBUTOR: CURTAIN WEIGHT: __________ 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 19: Installation Data Sheet

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Advanced Service Door Installation Data Sheet 1. INSTALLATION DATA SHEET A. Your "INSTALLATION DATA SHEET" looks like Fig. 3–A. It is found inside the door hardware box. You will need to refer to the data on this sheet during installation.
  • Page 20: Section 6

    Use through bolts to fasten the wall angle in the area above steel, Fig. 4–C. distance. Check for level and plumb. Apply welds as shown in Fig. 4–B, using welding electrodes E6010, E6011 or E7014. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007...
  • Page 21: Headplates, Stop Lock Brake & Barrel Assembly

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door 3. IDENTIFY HEADPLATE BRACKETS, Fig. 4–D(a) Non-Drive End Drive End Right hand drive is shown (left hand drive opposite). Headplate Headplate 4. IDENTIFY DRIVE END OF BARREL ASSEMBLY, Fig. 4–E Right hand drive is shown (left hand drive opposite). The drive end of barrel assembly typically is longer and has a smaller shaft diameter than the non-drive end.
  • Page 22: Mounting Barrel Assembly & Headplate Brackets

    G. Slide inner set collars and spacer collars against headplate bearings and tighten set screw on the set collars. (Spacer collar does not have set screw.) Tighten Drop Stop Device hub set screws. FIG 4-H 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 23: Hand Crank Operation

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door 9. HAND CRANK OPERATION E. Carefully and deliberately turn the crank handle to operate the door. (During installation you will be turning the barrel assembly.) WARNING F.
  • Page 24: Curtain Installation

    E. Remove bottom slat end lock and attach Sensing Edge. Clamp Washer F. Replace bottom slat end lock. Curtain Top Slat Stud WARNING Do NOT remove the slings or ropes at this time. Fig 4–K(b) 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 25: Guide Angle Installation

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door If you have welded "E" assemblies or "Z" assemblies factory assembled and have already installed them in a previous step, skip Step 10. Door Opening 11.
  • Page 26: Rotary Transducer

    Junction Box. This 7-pin connector cable will be attached to the Junction Box after the box is mounted. (Right hand installation shown for example only.) Fig 4–Q G. Remove locking pliers or other secure clamping device. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 27: Mounting/Connecting Electrical Components

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door DANGER LINE POWER should NOT be installed at this time. In the following steps electrical components will be physically mounted. Ensure that all incoming power supplies have been de-energized prior to beginning work on attachment of RapidSlat™...
  • Page 28: Junction Box

    26. BLACK PHOTO EYE CABLE 3. Photo Eyes will be aligned later, when power is applied to the Control Panel. See page 29 Fig 4–S(d) (From Receiver) Photo Eye Adjustment. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 29: Ballast Resistor

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door 14. MOUNTING ... (continued) E. The Ballast Resistor is required to absorb and dissipate electrical energy CAUTION! This surface may become hot! from the control panel’s VS (Variable Speed) drive as the door closes.
  • Page 30: Low Voltage Wiring

    TO MOTOR Fig 4–U MAIN MOTOR BALLAST right side of the Control Panel bottom. POWER RESISTOR • Connect 3-phase power lines to the line filter. The GROUND MAIN wire from the line filter to the ground lug is factory wired. POWER 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 31: Install Safety Labels

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Installation (continued) Advanced Service Door 17. INSTALL SAFETY LABELS, Fig. 4–V Product safety labels must be installed. A. Find Safety Labels in hardware box. Motor Brake B. Attach Motor Brake Release Pull Cord Tag to the motor pull cord.
  • Page 32: Install (Optional) Brush Seal

    Motion Sensor is an optional component purchased separately and does not come with door. A. Follow the installation instructions accompanying the Motion Sensor. B. Install wiring per wiring diagram on page 29. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 33: Installation Check List

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat Installation Check List ™ Advanced Service Door After completing the instructions contained in this section, the door assembly, Guide Angles, Motor, Junction Box, Rotary Transducer, Edge Sensor, Ballast Resistor, Photo Eyes, Stop Lock Brake, Hand Crank and Interlock Switch, and Control Panel should be mounted to the structure.
  • Page 34: Section 5

    3 phases. Consult your a licensed electrician if you have any questions. Overhead Door Corporation’s warranty will not cover damage caused by failure of the motor, control panel or other electrical components due to the use of an inadequately grounded system.
  • Page 35: 240V Motor Wiring

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ 240V Motor Wiring Advanced Service Door FACTORY WIRED, these steps and illustration are for reference only! SUMITOMO MOTOR NOTES: 1. Slide the three black motor wires through the LARGE suppression core (800358-0002).
  • Page 36: Main Component Overview

    WALL STATIONS IN IN/AUX IN2 MULTI-WIRE SIGNAL CABLE HOLES FOR POWER FOR: MAIN POWER MOTOR CABLE BALLAST RESISTOR BALLAST RESISTOR MOTOR CABLE RIBBON CABLE (34 WIRE) TO LOGIC BOARD MAIN POWER (FROM DISCONNECT) 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 37: Control Panel Contents

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Wiring Overview (continued) Advanced Service Door 208/240 VAC AUX 1 INVERTER AND Fig 5–G Control Panel Contents SWITCH SOCKET FOR TIMER CLOSE LOW VOLTAGE MOTOR SENSE (NOT PRESENT ON OPTIONAL LOOP...
  • Page 38: Control Panel Wiring Diagram

    3Ø POWER INPUT FROM DISCONNECTS OUTPUT CUSTOM WALL WALL OPTION CUSTOM STATION 2 STATION 1 LOOP BLOCK MODULE JUMPER NOTE: Add jumper from pin one to INSTALLER CONNECTION FACTORY WIRED GROUND pin four. (4X) 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 39: Control Panel Cables

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Wiring Overview (continued) Advanced Service Door Fig 5–I Control Panel - Cables to Connector Board A = 24VAC power A = Positioner Power A = 24VAC power Custom Use Custom...
  • Page 40: Junction Box Wiring

    (cable connections) This row of connectors may be expanded PHOTO EYE SENSING (if space is available) from 3 to 4 to add in the motion sensor. EDGE (From Hand Crank Interlock Switch) 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 41: Photo Eye Adjustment

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Wiring Advanced Service Door 2. PHOTO EYE ADJUSTMENT Photo Eye wiring connections were completed (GND) (GND) in a previous step (Mounting Electrical components on page 17). • Final adjustment of the Photo Eyes will be made after power is supplied to the door system.
  • Page 42: Control Wiring Low Voltage

    Custom Use when the system is functioning normally if the door Custom If used, wire at connector board AUX1 IN is idle. A display other than this indicates a problem. * FACTORY WIRED 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 43: Rotary Transducer Wiring Connections/Settings

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Wiring (continued) Advanced Service Door 4. ROTARY TRANSDUCER WIRING CONNECTIONS AND SETTINGS • The Rotary Transducer system is pre-wired at the factory. Sprocket Restraining Screw – The Rotary Transducer and bracket were mounted to the face of the Motor/Gearbox in Section 4, Step 12.
  • Page 44: Wiring Check List

    Fig 5–P(b) become interference). Control Panel illustrating – Ensure there are no loose tools or materials inside the Control cable positions Panel or Junction Box. TO PHOTO EYE RECEIVER TO MAIN POWER 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 45: Door System Set Up Procedures

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Section 6 Advanced Service Door Door System Set Up Procedures Calibration and Set Up Logic Board INITIAL STARTUP PROCEDURE (Located inside the Control Panel door) Lit when mains enabled on Motor Board SAFETY OUT 1.
  • Page 46: Initial Set Up Menu

    Push button Mode: Momentary or Constant-Stop or Constant Reverse. 11) Edge Disable NO –– Disable Edge Detector and correspondingly changes door closing speed. 12) Photo Eye Disable NO –– Disable Photo Eye and correspondingly changes door closing speed. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 47: Initial Set Up Procedure

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Calibration and Set Up (continued) Advanced Service Door INITIAL SET UP PROCEDURE 3. ENTER CALIBRATION MODE Operator is normally in RUN Mode. To make changes to system settings, you must switch to CAL Mode.
  • Page 48 7. Press and release the OPEN key. Verify the door moves in the open direction. If the door moves in the open direction, press SELECT and verify display reads "Jog/Pot Value - OFF". Initial Set Up tasks are complete, proceed to Motion Set Up Procedure, Step I on page 38. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007...
  • Page 49: Motion Set Up Menu

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Calibration and Set Up (continued) Advanced Service Door MOTION SET UP MENU * See WARNING below **Changes to these parameters will cause RapidSlat™ to The Control Panel display consists of two lines. The top line shows the name of the parameter.
  • Page 50: Motion Set Up Procedure

    Press the RUN/CAL key until reads "Idle: Down Limit - DnLmt--> UpLmt RunRead". This completes the Initial Set Up and Motion Set Up steps of the RapidSlat™ Door System. Begin Final Set Up steps on the next page. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007...
  • Page 51: Final Set Up Menu & Procedure

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Calibration and Set Up (continued) Advanced Service Door FINAL SET UP MENU & PROCEDURE 1. Press the Calibration push button on the Logic Board inside the Control Panel, Fig. 6–C (page 35) and close the Control Panel. Verify the front panel displays "INITIAL SET UP - SHOW OPTIONS".
  • Page 52: Panel Resets Menu & Procedure

    8. Press the Down ARROW and run the door to the Close limit. 9. Verify display reads "Idle Down Limit - ** Cycles". 9. Verify display reads "Idle Down Limit - ** Cycles". 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 53 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Calibration and Set Up (continued) Advanced Service Door PANEL RESETS MENU & PROCEDURE (continued) To Fix/Validate Panel Settings: (Ensure door is fully closed) To Update Maintenance/Service: (Ensure door is fully closed) Maintenance/Service 3.
  • Page 54: Information Menus

    Control Panel. If the panel is in a location where public access is possible, disable the Control Panel keypad and install a means to limit access to the inside of the panel. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007...
  • Page 55: Section 7

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Section 7 Advanced Service Door Special Door System Features Exterior Hood Installation CAUTION 1. PRE-HOOD CHECK LIST WARNING Extra care must be taken when installing optional accessories. Optional accessories must be installed in such a way that they do Improper use of Hand Crank can cause severe injury or death.
  • Page 56: Section 8

    Not Used DWN APP Not Used Normally Lit (OFF if jumper missing or optional switch is triggered.) Custom Use Fig 8–A Custom AUX1 IN If used, wire at connector board * FACTORY WIRED 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 57: Drop Stop Device Activation Indications

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ DROP STOP DEVICE ACTIVATION INDICATIONS Advanced Service Door The Stop Lock Brake is intended for emergency use ONLY and the operational life on this unit has a limited number of activations.
  • Page 58: Drop Stop Device Function

    TENSION SPRING CLIP TENSION ADJUSTMENT CLIP SPRING ROTOR HUB PAWL Please note that components and component locations are shown here for REFERENCE ONLY. LATCH Your unit installation and component locations may be different. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 59 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ DSD (DROP STOP DEVICE) FUNCTION CONTINUED... Advanced Service Door - After completing electrical connections with the operator, the door-closing test must be conducted with special care. CAUTION The pawl may engage the stator during door operation if Drop Stop Device (DSD) is improperly adjusted in the factory. When testing, keep your finger ready to push the STOP button instantly in the event that the pawl engages the stator.
  • Page 60: Drop Stop Device Spring Tension Adjustment

    Reduce spring tension as mentioned in prior test. Repeat test. Fig 8–G Fig 8–F 10oz. Weight 10oz. Weight When all tests can be conducted with success, that is, without any (Including Wire) (Including Wire) adjustments required, the DSD is ready for service. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 61: Logic Board Indications

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ LOGIC BOARD INDICATIONS Advanced Service Door TROUBLE POTENTIAL CAUSE NOTES / CORRECTIVE ACTION Control Panel has turned OFF power to AC Drive and motor brake. The panel Check keypad display and History Menus for cause of shutdown.
  • Page 62 If Wall Station 1 not being used: Jumper COM 1 to STOP on Connector Board Open Cancel: Stop PB Up request ignored, Wall Station Stop PB also pressed. If Wall Station 2 not being used: Jumper COM 2 to STOP on Connector Board 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 63: Control Panel Status Messages

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ CONTROL PANEL STATUS MESSAGES Advanced Service Door TROUBLE POTENTIAL CAUSE NOTES / CORRECTIVE ACTION Frequent false Overspeed Re-measure doors top speed using Item #2/Re-Record Overspd in "Panel Panel not recognizing actual speed.
  • Page 64 Door reversed by Microwave Entrapment device. Reversing: Photo Eye Door reversed by Photo Eye Entrapment device. Reversing: Edge Door reversed by Edge Bottom Bar Reversing edge. Reversing: EdgeLoss Door reversed by Edge Bottom Bar Signal Loss. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 65 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ CONTROL PANEL STATUS MESSAGES (continued) Advanced Service Door MESSAGE DISPLAYED CAUSE NOTES / CORRECTIVE ACTION Reversing: PB Release Door reversed from Wall Station PB release (constant-revmode). Displayed while closing door is reversing by release of one of the listed closing Reversing: Key Release Door reversed from keypad release (constant-rev mode).
  • Page 66 TC Holding: OpenAct Timed Close timer reset by Open Actuator. Check for obstructions. TC Holding: MwaveSaf Timed Close timer reset by Microwave Entrapment Protection Device. TC Holding: Edge Timed Close timer reset by Edge. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 67: Control Panel Alert Messages

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ CONTROL PANEL ALERT MESSAGES Advanced Service Door MESSAGE DISPLAYED CAUSE NOTES / CORRECTIVE ACTION ALERTS -MISCELLANEOUS In Menus - No Motion Not normally displayed, but will appear in Event Log.
  • Page 68: Control Panel Shutdown (Fault) Messages

    SHTDN Inv Lost 3 Phz Inverter fault from loss of three phase. Check incoming power for voltage balance between legs. SHTDN Inv Reject Cmd Inverter fault from illegal modbus request. Not field serviceable-contact service representative. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 69: Control Panel Fault+ Messages

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ CONTROL PANEL FAULT+ MESSAGES Advanced Service Door MESSAGE DISPLAYED CAUSE NOTES / CORRECTIVE ACTION FAULTS - INVERTER COMM SHTDN Inv UnExpt Run Check Communication Cable (phone cable) between Motor Board Inverter was unexpectedly running or unexpectedly stopped.
  • Page 70: Section 9

    Check Stop Lock Brake Manual Operation of Door • If the Stop Lock Brake has been activated replace the Stop • Inspect door alignment and level. Lock Brake. Fig 9–B • Inspect slats and endlocks for damage. • Inspect guides, sensing edge and hood for damage. Mounting Bolt Tightness Keep records of all service and maintenance. • Check fasteners anchoring headplates and door guides to wall. 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 71: Brake Gap Inspection & Adjustment

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Brake Gap Inspection and Adjustment Advanced Service Door 1. Fully close door, remove power. Hex head • Use proper lock out/tag out procedures. screw 2. Remove Winding Eye cover, Fig. 9–C.
  • Page 72: Section 10

    7/31/03 308126-0 Installation only) Warn Sensing Test without which Edge indication can fail operation daily. or death. can cause injury 4/13/93 607873-0001 (Drive End Cover) Fig 10–A PARTS LIST on next page 2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013...
  • Page 73: Table Of Part Numbers

    2013© Overhead Door Corporation www.overheaddoor.com 608905-0007 Rev 7-03-2013 RapidSlat ™ Illustrated Parts Breakdown (continued) Advanced Service Door Table of Part Numbers BEFORE ORDERING PARTS LOCATE YOUR ORIGINAL DOOR NUMBER Found on the Nameplate Attached to your Bottom Bar Reference Reference...
  • Page 74 If it is determined there is a defect, the Overhead Door Distributor will be credited the cost of the part. If it is determined there is not a defect in material and/or workmanship, no credit will be issued.
  • Page 75 WARRANTY ©Overhead Door Corporation Operation & Maintenance Manual: Rolling Doors...
  • Page 76: Return Goods Policy

    RapidSlat ® Rolling Service Doors Limited Warranty The Distributor of Overhead Door Corporation products whose name appears below ("Seller") warrants to the original ® purchaser of RapidSlat Series 611, 621 and 626 rolling service doors (“Product”), subject to all of the terms and conditions...
  • Page 77 Overhead Door Corporation 2501 S. State Hwy 121 Bus., Suite 200 Lewisville, TX 75067 1-800-929-3667(DOOR) www.overheaddoor.com...