  • Page 1 INSTRUCTION MANUAL Heavy Duty Control Unit...
  • Page 2: Packing List

    This manual corresponds to the following references: HDE-9UD (100V) HDE-1UD (120V) HDE-2UD (230V) Packing List The following items are included: HDE Heavy Duty Control Unit ....1 unit Power Cord ....1 unit Manual ......1 unit Ref. 0024077 (100V) Ref.
  • Page 3: Connection Example

    para manuales - color gris 200 mm Connection Example - Heavy Duty Handle 130 mm 130 mm HDE Heavy Duty Control Unit 100 mm 80 mm 60 mm 50 mm 40 mm C470 Cartridges Stand Cable T470F Ref. 0024227 Thermal Insulator Grip HD Handle Stand for T470 Heavy Duty...
  • Page 4 Connection Example - Nitrogen HD Handle supply either from N net or JBCs N generator. supply pressure range: Handpiece 3 to 6 bar (6 bar MAX) Tube HDE Control Unit from N Outlet* Inlet* from JBCs N generator MNE Nitrogen Flow Regulator Module Cable...
  • Page 5 130 mm HDE can be connected to FAE1 and FAE2 fume extractors. To do so, the HDE control unit must be updated with program version 8886784 (or later versions), which can be downloaded form JBC’s website at https://www.jbctools.com/software.html. 100 mm Once the station is updated, connect it to the fume extractor with the RJ12 cable, provided with FAE1 and FAE2.
  • Page 6 Compatibility Select the equipment that best suit your soldering or desoldering needs. Control Cartridge Tool Stand P-005 Unit Range T470 T470S T470Z C470 T470F HT470* HDTS T470N * It works with two HDE Control Units...
  • Page 7 para manuales - color gris 200 mm DDE Work Screen HDE Work Screen 130 mm 130 mm DDE offers an intuitive user interface which provides quick access to station parameters. HDE offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105 Default PIN: 0105 100 mm...
  • Page 8: Advanced Functionalities

    Insert a USB flash drive into the USB-A connector to save your soldering process in csv format. Files Station update Download the JBC Update File from www.jbctools.com/software.html Insert the USB flash drive with the file downloaded to the station. Update System Notifications The following icons will be displayed on the screen’s status bar.
  • Page 9: Peripheral Setup

    ºC para manuales - color gris 200 mm 19:29 T470 Temp levels ºC Power Port Peripheral Set Up 130 mm 130 mm Temp levels 1. After connecting the module, enter the 19:29 Peripherals Menu and select the port which Power Port you want to join with the module.
  • Page 10: Usb Connector

    Power Power Port Port USB Connector Download the latest software from our website to improve your soldering station at www.jbctools.com/software.html.
  • Page 11: Operation

    130 mm 130 mm JBC’s Most Efficient Soldering System Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user can work at a lower temperature and improve the soldering quality. The tip temperature is further 100 mm reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.
  • Page 12: Maintenance

    If necessary use a tool to lever it off. and replace it in the station. - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service.
  • Page 13 para manuales - color gris 200 mm Safety 130 mm 130 mm It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. 100 mm - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire. - The power cord must be plugged into approved bases.
  • Page 14 Notes...
  • Page 15: Specifications

    Specifications 130 mm 130 mm Heavy Duty Control Unit Ref. HDE-9UD 100V 50/60Hz. Input fuse: 4A. Output: 42V. 100 mm Ref. HDE-1UD 120V 50/60Hz. Input fuse: 4A. Output: 42V. Ref. HDE-2UD 230V 50/60Hz. Input fuse: 2A. Output: 42V. - Output Peak Power:...
  • Page 16 In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.

This manual is also suitable for:

Hde-1udHde-2ud002407700237170024080Hde series

Table of Contents