Hoover HT6360IN/1 Instruction Manual page 8

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
the hood will be closed, the hood enters into standby mode, and recycle by circle.
The speed buttons and lamp button can work separately and not controlled by the
power button. Press one function button, the hood will work at that function status.
Press power button at any status will close all function operation.
3. Press lamp button
and power button
Indicator light of lamp button
this.
4. Press the
(High) button one time, motor runs on high speed, the indicator light
of high button
the motor will stop. Indicator light of high button and power button will be off,and
recycle by circle.
5. Press the
(Mid) button one time, motor runs on middle speed, the indicator light
of middle button
and the motor will stop. Indicator light of middle button and power button will be
off,and recycle by circle.
6. Press the
(low) button one time, motor runs on low speed, the indicator light of
low button
motor will stop. Indicator light of low button and power button will be off,and recycle
by circle.
Low speed, mid speed and high speed cannot work at the same time. When hood is
on high speed, press low speed, it will turn to low speed at once; when it is in low
speed, press middle speed, it will turn to middle speed immediately, and so on.
TROUBLESHOOTING 
Fault 
Light on, but motor
does not work
Light does not
work, motor does
not work
Oil leakage
once; lights will be turn on. Indicator light of lamp button
will lit on. Press lamp button
and power button
and power button
and power button
and power button
Possible Cause 
Fan switch turned off
Fan switch failed
Motor failed
House fuses blown
Power cord loose or
disconnected
One way valve and the outlet
are not tightly sealed
Leakage from the connection of
chimney and cover
will be off. And recycle like
 
will beam. Press high button
will beam. Press middle button
will beam. Press low button
Select a fan switch position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Take down the one way valve
and seal with sealant.
Take chimney down and seal.
8
again to turn off the lights.
again and
again and the
Solution 
again