Understand manual before use. Operating AMKUS Rescue Systems without understanding
DANGER
the manual, receiving proper training, and using appropriate personal protective equipment is
a misuse of AMKUS equipment. This manual does not fully address safety. Additional safety
information is published in AMKUS Safety Manual LAA-001. Obtain safety information at
www.amkus.com/
Certified Model NFPA 1936
EN13204 Designation: ATO
Thank you for choosing AMKUS Rescue Systems. Read this User
Information Manual thoroughly. If you have any questions, please
contact your local dealer or AMKUS Rescue Systems.
Please complete the tool registration form included with your
equipment and return it to AMKUS Rescue Systems. You may also
register your equipment on-line at www.amkus.com.
The serial number for your power unit is identifi ed on the product
label which is located on the yellow hydraulic fl uid reservoir. Please
have the serial number available if you need to contact your local
dealer or AMKUS Rescue Systems.
AMKUS RESCUE SYSTEMS
www.amkus.com
©Copyright Amkus Rescue Systems, Inc. 2015 - 2017
2015 Edition
GH2S2XLNT Power Unit
User Information Manual
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response
equipment and services want responders to know and understand the
following:
1. Firefi ghting and Emergency Response are inherently dangerous activities
requiring proper training in their hazards and the use of extreme caution
at all times.
2. It is your responsibility to read and understand any user's instructions,
including purpose and limitations, provided with any piece of equipment
you may be called upon to use.
3. It is your responsibility to know that you have been properly trained in
Firefi ghting and /or Emergency Response and in the use, precautions, and
care of any equipment you may be called upon to use.
4. It is your responsibility to be in proper physical condition and to maintain
the personal skill level required to operate any equipment you may be
called upon to use.
5. It is your responsibility to know that your equipment is in operable
condition and has been maintained in accordance with the manufacturer's
instructions.
6. Failure to follow these guidelines may result in death, burns or other
severe injury.
Fire and Emergency Manufacturers and Service Association
FEMSA
4201 Montdale Drive, Valparaiso, IN 46383-4098 USA
800-592-6587 • 219-548-5000 • Fax 219-476-1669
DANGER
P.O. Box 147, Lynnfi eld, MA 01940 • www.FEMSA.org
LAP-010 March 16, 2017 Rev02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GH2S2XLNT and is the answer not in the manual?

Questions and answers

Summary of Contents for Amkus GH2S2XLNT

  • Page 1 DANGER the manual, receiving proper training, and using appropriate personal protective equipment is a misuse of AMKUS equipment. This manual does not fully address safety. Additional safety information is published in AMKUS Safety Manual LAA-001. Obtain safety information at www.amkus.com/...
  • Page 2 CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor CAUTION or moderate injury. NOTICE is used to address practices not related to physical injury. NOTICE ©Copyright Amkus Rescue Systems, Inc. 2015 - 2017 LAP-010 March 16, 2017 Rev02...
  • Page 3: Specifications

    Always wear appropriate apparel. CAUTION AMKUS equipment is manufactured with superior craftsmanship and quality that is backed by a factory warranty. AMKUS cannot control how other manufacturers of rescue tools rate, test and warranty their equipment. Therefore, we do not recommend that tools other than AMKUS be connected to our equipment.
  • Page 4 Be careful not to lose it! Allow the hydraulic fl uid to drain. Clean and replace the drain plug. Fill the hydraulic fl uid reservoir with new AMKUS mineral base hydraulic fl uid. Replace the fi ll plug/vent cap.
  • Page 5: Setup Procedure

    3. Next, remove the hydraulic fl uid reservoir fi ll plug/vent cap. Fill the hydraulic fl uid reservoir with approximately 2.0 gallons U.S. (7.6 liters) of AMKUS mineral base hydraulic fl uid. The fl uid should reach a level that fi lls approximately 1/2 of the sight gauge window.
  • Page 6: Part Identification

    When you have fi nished operations, follow the instructions in the engine owner’s manual to stop the engine. 9.0 PART IDENTIFICATION Fuel Cap Engine Oil Fill Cap Selector Valve Knobs Fill Plug / Vent Cap Hydrolic Fuel Reservoir Drain Plug ©Copyright Amkus Rescue Systems, Inc. 2015 - 2017 LAP-010 March 16, 2017 Rev02...
  • Page 7 10.0 TROUBLE SHOOTING GUIDE Any problem not resolved by these suggestions may require you to contact your local dealer or AMKUS, Inc. for further guidance. PROBLEM SOLUTION Engine will not start or poor engine performance Check owner’s manual troubleshooting guide.
  • Page 8 3. Inspect the poser unit, hoses, fi ttings and couplings after each use for damage, leakage and excessive wear. 4. If damage or excessive wear is noticed, do not use the power unit; contact your local dealer or AMKUS Rescue Systems.

Table of Contents