The serial number for your power unit is identified on the product label which is located on the yellow
hydraulic fluid reservoir. For quick reference, record the serial number on the cover of this manual.
Please have the serial number available if you need to contact your local dealer or AMKUS, Inc.
DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with EN ISO 4871
Measured A-weighted emission sound pressure level, L
Uncertainty, K
, in decibels: 1.5
pA
Measured A-weighted sound power level, L
Uncertainty, K
, in decibels: 1.5
WA
Values determined according to Annex B of EN 13204 using the basic standards
EN ISO 3744 and EN ISO 11201.
Note: The sum of a measured noise emission value and its associated uncertainty represents an
upper bound of the range of values which can occur in measurements.
AMKUS RESCUE SYSTEMS
amkus.com
©Copyright Amkus Rescue Systems, Inc. 2010-2020
Do not use this product until you have read this manual and understand all
safety and operating instructions! Failure to comply with these warnings and
instructions may result in serious injury, disease, illness or death.
EN13204 Designation: MTO
Serial Number
Manual: GB2S-XLO Power Unit
_______________________
Please read this User Information Manual
(ref. 20µPa), in decibels: 88.2
pA
(ref. 1 pW), in decibels: 100.2
WA
4201 Montdale Drive, Valparaiso, IN 46383-4098 USA
800-592-6587 • 219-548-5000 • Fax 219-476-1669
LAP-005 JUNE 22, 2020 Rev05

Advertisement

loading
Need help?

Need help?

Do you have a question about the GB2S-XLO and is the answer not in the manual?

Questions and answers

Summary of Contents for Amkus GB2S-XLO

  • Page 1 For quick reference, record the serial number on the cover of this manual. Please have the serial number available if you need to contact your local dealer or AMKUS, Inc. DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with EN ISO 4871 Measured A-weighted emission sound pressure level, L (ref.
  • Page 2 Fill the hydraulic fluid reservoir with approximately 2.0 protection from those hazards to which personnel are gallons U.S. (7.6 liters) of AMKUS mineral base hydraulic exposed or could be exposed while working with this fluid. The fluid should reach a level that fills approximately Always wear appropriate apparel! of the sight gauge window.
  • Page 3 10,000 psi and 11,000 psi. If you have a reading outside of that range, contact Selector your local dealer or AMKUS, Inc. DO NOT ATTEMPT TO Valve Knob ADJUST THE PRESSURE RELIEF SETTING! Routine Maintenance for Hoses...
  • Page 4 Any problem not resolved by these suggestions may cleaned periodically. Be aware that while the couplings require you to contact your local dealer or AMKUS, Inc. for may be clean, the dust caps will accumulate dirt during use. further guidance.