Amkus GH2A-MC Series User's Information Manual

Amkus GH2A-MC Series User's Information Manual

Mini power unit

Advertisement

Quick Links

Understand manual before use. Operating AMKUS Rescue Systems without understanding
DANGER
the manual, receiving proper training, and using appropriate personal protective equipment is
a misuse of AMKUS equipment. This manual does not fully address safety. Additional safety
information is published in AMKUS Safety Manual LAA-001. Obtain safety information at
www.amkus.com/
This manual is intended for use with manuals published by manufacturers of the prime movers (engine and
pump) used in this power unit.
GH2A-MC
Power unit with cage
AMKUS RESCUE SYSTEMS
www.amkus.com
©Copyright Amkus Rescue Systems, Inc. 2015 - 2017
GH2A-MC Series Mini Power Unit
User Information Manual
Power unit with carrying handle
4201 Montdale Drive, Valparaiso, IN 46383-4098 USA
800-592-6587 • 219-548-5000 • Fax 219-476-1669
SAFETY MANUAL for AMKUS
RESCUE SYSTEMS
Understand manual before use. Operating AMKUS Rescue Systems without understanding the
DANGER
manual, receiving proper training, and using appropriate personal protective equipment is a
misuse of AMKUS equipment. Obtain safety information at www.amkus.com/
This Safety Manual is intended to familiarize rescue workers and maintenance personnel with the safety messages of AMKUS
Rescue Systems, including powered rescue tools (rams, cutters, spreaders, combination tools), power units (electric or gasoline
driven), and powered rescue tool components (cable assemblies, hose assemblies, hose reels, etc.). The safety messages in this
publication supersede safety information appearing in AMKUS publications prior to April 2016.
This manual is intended for use with manuals published by manufacturers of prime movers (engines, electric motors, and pumps)
used in AMKUS power units.
This manual does NOT address operation or servicing of AMKUS Rescue Systems. Only competent rescue tool repair technicians
are quali ed to repair AMKUS equipment. This manual should be available to all personnel involved with AMKUS equipment.
AMKUS RESCUE SYSTEMS
4201 Montdale Drive, Valparaiso, IN 46383-4098 USA
800-592-6587 • 219-548-5000 • Fax 219-476-1669
www.amkus.com
©Copyright Amkus Rescue Systems, Inc. 2016
Amkus Safety Manual LAA-001
Certified Model NFPA 1936
2015 Edition
EN13204 Designation: ATO
GH2A-MCH
LAA-001 April 15, 2016 Rev00
LAP-006 June 8, 2017 Rev05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GH2A-MC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Amkus GH2A-MC Series

  • Page 1 This manual does NOT address operation or servicing of AMKUS Rescue Systems. Only competent rescue tool repair technicians are quali ed to repair AMKUS equipment. This manual should be available to all personnel involved with AMKUS equipment. AMKUS RESCUE SYSTEMS 4201 Montdale Drive, Valparaiso, IN 46383-4098 USA 800-592-6587 •...
  • Page 2 CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor CAUTION or moderate injury. NOTICE is used to address practices not related to physical injury. NOTICE ©Copyright Amkus Rescue Systems, Inc. 2015 - 2017 LAP-006 June 8, 2017 Rev05...
  • Page 3 770 cc/min second stage Fluid Type: AMKUS MV1 Mineral Base Hydraulic Fluid. Safety Data Sheet (SDS) for AMKUS MV1 Hydraulic Fluid is available at AMKUS.com and CHEMTREC.com (For equipment stored and operated in environments below 32 deg. F (0 deg C) contact Amkus Rescue Systems for recommendation.
  • Page 4 Engine Choke Control Fill Plug/Vent Cap Sight Glass Safety Label Throttle Hydraulic Fluid Reservoir Standard Couplings Selector Valve Knob Serial Number Label Mono Couplings SEI Compliant Label ©Copyright Amkus Rescue Systems, Inc. 2015 - 2017 LAP-006 June 8, 2017 Rev05...
  • Page 5 3. Next, remove the hydraulic fluid reservoir fill plug/vent cap. Fill the hydraulic fluid reservoir with approximately .68 gallons U.S. (2.57 liters) of AMKUS mineral base hydraulic fluid. The fluid should reach a level that fills approximately ½ of the sight gauge window.
  • Page 6 6.0 GETTING STARTED Connect the tool connection hoses to the hose lines from the AMKUS hydraulic power unit. 1. For power units equipped with standard couplings: The male and female couplings on the tool connection hoses should be connected to the corresponding male and female couplings on the hose lines leading from the power unit. To connect the couplings, twist the sleeve on the female coupling so that the notch in the sleeve lines up with the pin.
  • Page 7 8.0 TROUBLE SHOOTING GUIDE Any problem not resolved by these suggestions may require you to contact your local dealer or AMKUS, Inc. for further guidance. PROBLEM SOLUTION Engine will not start or poor engine performance Check Honda owner’s manual. Rescue tool lacks power or speed Check hydraulic fl...
  • Page 8 BEFORE BEING PLACED BACK IN SERVICE, power units must be inspected to this checklist; 1. Check to see that all markings are legible. Contact your local dealer or AMKUS Rescue Systems for replacement labels. 2. Wipe tool, hoses, fittings and couplings clean (see routine maintenance for hoses and couplings).

This manual is also suitable for:

Gh2a-mcGh2a-mch

Table of Contents