Page 1
This manual should be kept available to all operating and maintenance personnel. This manual does NOT address servicing of AMKUS Rescue Systems. Only competent rescue tool repair technicians are qualified to repair AMKUS equipment.
Page 2
DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following: Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times. 2.
Seek medical attention immediately. Avoid the urge to contain leaks with hands. Injection injuries require immediate medical attention. Safety Data Sheet (SDS) for AMKUS MV1 and AMKUS MV0 Hydraulic Fluid is available at AMKUS.com and CHEMTREC.com Hydraulic leaks can occur from situations such as: •...
Page 6
Risk of injury increases in unfavorable conditions such as poor lighting, inclines, loose, wet, or icy surfaces. Follow accepted safe lifting practices. Use of hydraulic fluids other than AMKUS MV1 or MV0 (see Specifications for fluid for specific tool NOTICE lines) can result in equipment damage and loss of function.
AMKUS uses another industry first, Variable Frequency Drives to regulate electrical requirements. This infinitely customizable control system is set up to require only 5 amps of current at start up. Unlike other electric power units, the 240SS increases electrical power as the pressure increases through the use of a Programmable Logic Controller (PLC).
INSTALLATION SITE SELECTION When selecting a location to mount the 240SS system it is important to install it inside a compartment away from the elements. For more information contact your local AMKUS dealer. AMKUS equipment is manufactured with superior craftsmanship and quality that is backed by the standard warranty which is published on the AMKUS website.
Connect the pressure and return hoses as follows: If AMKUS standard couplers are being used, be sure the pressure line has a male coupler at the end of the reel. The return line will have a female coupler at the end of the reel.
7.2.6 CONTROL PANEL The 240SS Control Panel houses a display and 5 buttons used to operate the unit. The green button is used to start/stop the entire system. Each reel circuit has a motor button and valve control button. Refer to the operating section of this manual for further explanation of button functions.
Page 16
15. Install Couplings Pressure Return Line Line If AMKUS standard couplers are being used, place the male coupler on the pressure line and the female coupler on the return line. Repeat for the other reel. Fluid Flowing From The...
GENERAL The 240SS is a simultaneous operation power unit. Two tools can be connected to a single power unit and operated either independently or simultaneously. To operate the 240SS. Ensure there is power to the unit. Begin operation by pressing the system start button.
Check the hydraulic fluid level sight gage after every use. Fluid should be “clear-gold”. Cloudy, milky, brownish, or smelly fluid indicates contamination. Contact your local dealer or AMKUS Rescue Systems. A noticeable drop in fluid level indicates fluid loss. Investigate and correct the cause of loss, add MV1 hydraulic fluid as needed.
11.4 2ND GENERATION 240SS BATTERY REPLACEMENT 240SS units manufactured after June, 2018 (models with a touch screen) contain a coin cell battery. Need for a battery change is rare and indicated by the touch screen remaining dark after the unit is powered on and running.
Contact your local dealer or AMKUS Rescue Systems for service. 6. Check the hydraulic fluid levels after each use. Replenish as necessary with AMKUS MV1 mineral based hydraulic fluid. Any equipment failing any part of this checklist is unsafe for use and must have the problem WARNING corrected before use or being placed back in service.