8.5.3

Manual mode

This mode can be used for a large project, e.g. a building which has no more than 63 floors
above the ground floor. Please see "Configure mode overview" chapter for more details.
This mode gives you complete freedom when configuring the settings.
There are 3 events that need to be set in manual mode:
1. Unlock event
In this event, the elevator will be called to the floor where the outdoor station is installed,
and the designated floor will be authorized for a period of time.
This event contains 4 scenarios:
The resident releases the lock via the indoor station or App in standby status.
The resident releases the lock via the indoor station during an incoming call.
The resident releases the lock via the indoor station during surveillance.
The resident releases the lock via the outdoor station when swiping the card or entering
the unlock password.
2. Calling the elevator from indoor station
In this event, the elevator will be called to the floor where the resident lives.
3. Authorization Flat to Flat
During an intercom call between two flats in the same building, when someone presses the
call authorization button at any time, the corresponding floor will be authorized within a
specified time.
Product manual 2TMD041800D0042