Download Print this page
Boston Acoustics PowerVent PV400 Service Manual

Boston Acoustics PowerVent PV400 Service Manual

Hide thumbs Also See for PowerVent PV400:

Advertisement

Quick Links

PV400
PV600
SERVICE GUIDE - PV600
PV800
PowerVent
Powered Subwoofers
®

Advertisement

loading

Summary of Contents for Boston Acoustics PowerVent PV400

  • Page 1 PV400 PV600 SERVICE GUIDE - PV600 PV800 PowerVent Powered Subwoofers ®...
  • Page 2: Specifications

    Specifications PV800 PV600 PV400 Frequency Response (±3dB) 26–150Hz 29–150Hz 44–150Hz Subwoofer Amplifier Power 300 watts continuous, 4Ω 120 watts continuous, 4Ω 65 watts continuous, 4Ω <0.5% THD, 250 watts, <0.5% THD, 100 watts, <0.5% THD, 50 watts, 20–150Hz 20–150Hz 20–150Hz Subwoofer Crossover 50–150Hz 75–150Hz...
  • Page 3 Connections NOTE: Power is always supplied to the subwoofer electronics unless it is unplugged. The auto-on circuitry only activates or deactivates the power amplifier. Make sure your subwoofer and receiver are unplugged when making the connection. Line level: Use the line level in with most systems. These inputs accept the line level signal from your receiver’s subwoofer output.
  • Page 4 If you do not wish to run RCA cables to your subwoofer, you may use speaker wire to connect the subwoofer in parallel with your main speakers. The subwoofer does not present any addi- tional load to your receiver. Select “subwoofer-no” from your receiver’s set-up menu. This sends the LFE signal to the main left and right speakers, and thus, to the subwoofer.
  • Page 5 Connecting Your Subwoofer to Stereo or Dolby ® Pro Logic ® Systems For stereo or Dolby Pro Logic systems, the easiest method is to use speaker wire connections as shown. BACK OF RECEIVER You may also use the “sub out” connection from your receiver to the input on the subwoofer marked use crossover control.
  • Page 6 Controls Volume: Adjusts the sound level of the subwoofer. A typical setting is around 10 o’clock. Crossover (Hz): Adjusts the frequency of the low-pass filter for the subwoofer. Polarity (0° or 180°): Selects regular (0°) or inverted (180°) polarity for the subwoofer. Set this switch to provide the fullest, most dynamic bass.
  • Page 7 Item: PV600 PV600 10" BLACK POWERED SW (KK) EA Alternate: Primary UOM: EA Rev: Item Level Item Description Rev UOM Quantity --------- ---- --------------- ---------------------------------------- --- --- ----------- 010-001015-0 WOOFER 10" PV600 1.00 011-000334-0 TOP PLATE 42.5X93.5X6.0 1.00 011-000439-1 BACK PLATE/POLE PIECE 38X23.32X11.8 1.00 011-000502-0 BASKET 10"...
  • Page 8 PV600 Amplifier Parts List COMPONENT DESCRIPTION LOCATION MAIN BOARD COMPONENTS 600063 PCB, MAIN BOARD PSW-140 REVISION CC0087 CAP, CA .01UF 100V 20% DS0001 RECT, 100mA 75V SIGNAL 1N4148T D2,D3,D4,D5 DZ0021 ZENER, 500MW 15V 5% 1N5245B DZ0033 ZENER, 500MW 16V 5% 1N5246B RC0003 RES, CF 1K0 1/4W 5% R81,R82...
  • Page 9 PV600 Amplifier Parts List COMPONENT DESCRIPTION LOCATION EQ BOARD COMPONENTS 630038 PCB, INPUT EQ PV600 REVISION UA0003 OPAMP, QUAD 14PIN DIL LM324N U1,U2,U4 UA0009 OPAMP, QUAD 14P DIL TL074/084 CC0025 CAP, CA 1000PF 100V 10% CC0072 CAP, CA 100PF 100V 10% C1,C12,C14,C15,C23 CC0082 CAP, CA .1UF 50V 20%...
  • Page 10 PV600 Amplifier Parts List COMPONENT DESCRIPTION LOCATION VOLUME BOARD COMPONENTS 610035 PCB, CONTROL VOLUME PV600/800 REVISION JH0028 CNCTR, HEADER 3PIN .100CTR RP0047 POT, A100K SINGLE/ BRACKET 10% FINISHING COMPONENTS 480098 SUB, #16B 15" 187X032/187X032 SPEAKER WIRE, ECR 09/02/99 JODI 480099 SUB, #16R 15"...
  • Page 13: Equipment Required

    PERFORMANCE TEST / ALIGNMENT OF PV600 AMPLIFIER EQUIPMENT REQUIRED: Audio Signal Generator (20-20Khz, output adjustable up to 2V RMS) Dummy Load (4 ohm, 150 watt minimum) Digital multimeter Oscilloscope (dual trace) Test leads / interconnect cables, as required INITIAL INSPECTION: Before plugging the unit in and applying power, check for the following: loose, frayed or chafed power cable, speaker leads and other wiring bent, broken or damaged circuit cards and components...
  • Page 14 1. Attach a PV600/800 volume control assembly to the connector on the EQ PCB (see Figure 2). Turn the VOLUME knob to “0” (fully counterclockwise). 2. Remove jumper from the “BIAS” receptacle on the MAIN PCB (see Figures 2 & 3). Connect a milliammeter between the pins on the receptacle.
  • Page 15: End Of Test

    8. Disconnect signal generator from “USE CROSSOVER CONTROL”, and connect to “BYPASS CROSSOVER CONTROL” RCA jack. Turn CROSSOVER control counterclockwise. Displayed wave should not change as control is rotated. 9. Switch POLARITY switch from 0 to 180 deg. Phase of Ch. 1 waveform should shift 180 deg.
  • Page 16 PV600 Troubleshoot Guide June 2006 Symptom Cause/Location Cure Part ID Part Number PV 600 Blows Fuses OUTPUT DEVICES-PWR BRD REPLACE Q6-Q7 Q6-IRF9540 & Q7-IRF640 RECTIFIERS-PWR BRD REPLACE Q1-Q2-Q3 Q1-TIP29C, Q2-TIP30C, Q3-2N5401 LOW OUTPUT N-CHANNEL JFETS-CNTRL BRD REPLACE Q1 & Q6 Q1-J111, Q6-J111 TRANSISTOR- PWR BOARD REPLACE...

This manual is also suitable for:

Powervent pv600Powervent pv800