4 Mechanical Mounting

4.7 Wall-Mounted Installation

Mounting Steps
Step 1: Level the assembled mounting-bracket by using a level, and mark the positions for drilling holes on the
installation site.
Step 2: Insert the expansion bolts into the holes and secure them with a rubber hammer. Fasten the nut with a wrench
to expand the bolt. Remove the nut, spring washer, and flat washer, and store them properly.
Step 3: Fix the mounting-bracket with the expansion bolts.
(Note: No expansion bolt is supplied.)
Note: No expansion bolt is supplied.

4.8 Inverter Installation

Step 1: Take out the inverter from the packing carton.
Step 2: Hoist the inverter to the installation position when necessary (refer to "4.3.2 Hoisting Transport"). If the
installation position is not high enough, skip performing this step.
Step 3: Hang the inverter to the mounting-bracket and ensure that the mounting ears perfectly engage with the
mounting-bracket.
Step 4: Fix the inverter with screws M6x30.
FIG 4-11 Install the wall bracket
FIG 4-12 Install the inverter
M10
30N.m
M6
4.5
N.m
13 / 41