Indoor Unit Enabling Switches

OFF
1 2 3 4
ON
OFF
OFF
ON
OFF
ON
OFF
ON
• One main circuit board can control 4 groups (indoor unit
groups 0 – 3).
• Set to "disable" if the indoor unit group does not exist. Set to
"enable" if the indoor unit group exists.

Setting Switches

1 2 3 4 5 6 7
6
-
OFF
-
-
-
O
O
O
O
Not used (Be sure to set to OFF.)
OFF Central/individual setting is according to the
central control device (normal setting).
ON
Central/individual setting is always set to "individual."
OFF Control temperature is used for the room
temperature (normal setting).
ON
Inlet temperature is used for the room temperature.
Not used (Be sure to set to OFF.)
OFF
Communicate as a "sub" central control device.
ON
Communicate as a "main" central control device.
• If there are no central control devices other than this
interface, set to "main" (ON).
• To set this interface as the main, set only node 0 to
"main" (ON).
• If using in combination with an communication adapter,
AMY adapter, intelligent controller, or system controller,
set to "sub" (OFF).
• If using in combination with an ON/OFF controller, set the
ON/OFF controller as the main if the ON/OFF controller's
remote-controller prohibit function is to be used. If this
interface's remote-controller prohibit function is to be
used, set this interface as the main.
Pana̲CZ-CLNC1U̲Eng.indd   6
Pana̲CZ-CLNC1U̲Eng.indd   6
Indoor unit group 3 is disabled.
Indoor unit group 3 is enabled.
Indoor unit group 2 is disabled.
Indoor unit group 2 is enabled.
Indoor unit group 1 is disabled.
Indoor unit group 1 is enabled.
Indoor unit group 0 is disabled.
Indoor unit group 0 is enabled.
O: ON -: OFF R/C: Remote Controller
Option 1
Option 2
7
8
-
-
R/C prohibit
Fan speed
O
-
R/C prohibit
Air direction
-
O
R/C prohibit
Filter sign
O
Fan speed
Air direction
-
-
Fan speed
Filter sign
O
Air direction
Filter sign
-
---
---
-
O
---
---
O
O

Address Switches

1 2 3 4 5 6
OFF
O : ON
Address switch
1
2
3
4
5
6
-
-
-
-
-
-
O
-
-
-
-
-
-
O
-
-
-
-
O
O
-
-
-
-
-
-
O
-
-
-
O
-
O
-
-
-
-
O
O
-
-
-
O
O
O
-
-
-
-
-
-
O
-
-
O
-
-
O
-
-
-
O
-
O
-
-
O
O
-
O
-
-
-
-
O
O
-
-
O
-
O
O
-
-
-
O
O
O
-
-
O
O
O
O
-
-
-
-
-
-
O
-
O
-
-
-
O
-
-
O
-
-
O
-
O
O
-
-
O
-
-
-
O
-
O
-
O
-
O
-
O
-
-
O
O
-
O
-
O
O
O
-
O
-
-
-
-
O
O
-
O
-
-
O
O
-
-
O
-
O
O
-
O
O
-
O
O
-
-
-
O
O
O
-
O
-
O
O
O
-
-
O
O
O
O
-
O
O
O
O
O
-
-
-
-
-
-
O
O
-
-
-
-
O
-
O
-
-
-
O
O
O
-
-
-
O
-
-
O
-
-
O
O
-
O
-
-
O
-
O
O
-
-
O
O
O
O
-
-
O
-
-
-
O
-
O
O
-
-
O
-
O
-
O
-
O
-
O
O
O
-
O
-
O
-
-
O
O
-
O
O
-
O
O
-
O
-
O
O
O
-
O
O
O
O
O
-
O
-
-
-
-
O
O
O
-
-
-
O
O
-
O
-
-
O
O
O
O
-
-
O
O
-
-
O
-
O
O
O
-
O
-
O
O
-
O
O
-
O
O
O
O
O
-
O
O
-
-
-
O
O
O
O
-
-
O
O
O
-
O
-
O
O
O
O
O
-
O
O
O
-
-
O
O
O
O
O
-
O
O
O
O
-
O
O
O
O
O
O
O
O
O
O
O
- : OFF
Central control
address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
6
2011/11/11   12:23:42
2011/11/11   12:23:42

Advertisement

Table of Contents
loading

Table of Contents