Information Needed By User; Troubleshooting; Maintenance Of The Product; Cleaning The Sprayer - Jacto HD-400U Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

Band width
0.5
(m)
Distance to
50.5
walk (m)
Attach the calibrator bottle to the lance as shown:
1.
Remove the cap, nozzle and filter.
2.
Mount the calibrator cover to the lance.
3.
Reinstall the filter, nozzle and cap.
4.
Screw the calibrator onto the cover.
Record the time it takes to
walk 25 m²
• Hold the lance at the normal working height and spray into the bottle while
walking the distance required to spray an area corresponding to 25 m².
• Place the bottle on a level surface and observe the liquid level visible through
the side of the bottle. Match the liquid level to the corresponding scale on
the calibrator bottle.
• Empty the bottle and repeat this operation to determine the average of two
or more readings.
NOTE: For the volume in liters per bushel (L / alk), simply multiply the value obtai-
ned in liters per hectare (L / ha) by 2.42.
WARNING!
Wear a protective clothes to do the maintenance and
parts replacement.

5. Information Needed by User

5.1. Troubleshooting

• Put about 2 liters of water in the tank.
• While operating the lever, look into the tank to see how the problem arises.
• Refer to the table and diagram below.
6/36
0.7
1.0
1.2
1.5
35.7
25.0
20.8
16.7
Lance
Cover
Filter
Nozzle
Nozzle cap
Calibrator bottle
Simulate the spraying
of 25 m²
DESCRIPTION
Leakage through the cylinder
upper part.
After pumping and
pressurizing the chamber, as you
operate the lever it drops fast.
due to wear or impurities.
After pumping and
pressurizing the chamber, the
lever rises quickly when released.
due to wear or impurities.

5.2. Maintenance of the product

Every 40 hours, clean the chamber and lubricate all the components. Use a pliers
to disassemble the parts and a brush with nylon bristles clean and neutral deter-
gent. Always use personal protective equipment (PPE).

5.3. Cleaning the sprayer

After finishing the spray application, clean and wash all equipment in an approved
decontamination area.
Operate the lever for the internal cleaning of the camera.
Remove the chamber and lubricate the piston.

5.4. Drainage

You must drain it when you finish the use.

5.5. The consequences of improper service

Do not change the sprayer components. Always check for leaks or malfunction.
Follow the maintenance instructions and use original parts provided by Jacto.
Failure to follow the instructions may cause damage to the operator's health and
the environment.
CAUSES
CORRECTIONS
Worn or dried out
Replace or lubricate
piston cup.
the pump.
Cylinder valve
Clean or replace
not sealing properly
the valve.
Chamber valve
Clean or replace
not sealing properly
the valve.