Service Manual
Micro-switch SW5 is for setting the master or slave unit when the unit is in twin
connection.
Range: Master no slave (Normal 1 drive 1 connection), Master (2
positions without difference), Slave
Figure 57
Micro-switch SW6 is for selection of temperature compensation in heating mode.
This helps to reduce the real temperature diff erence between ceiling and fl oor so
that the unit could run properly. If the height of installation is lower, smaller value
could be chosen.
Range: 6 °C, 4 °C, 2 °C, E function (reserved for special customizing)
Figure 58
4 4 |
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump (11.2022)
Micro-switch S1 and dial-switch S2 are for address setting when you want to
control this unit by a central controller.
Range: 00-63
Figure 59