6.4.6 Dry mode
In dry mode, AC operates the same as auto fan in cooling mode.
All protections are activated and operate the same as they do that in
cooling mode.
Low Room Temperature Protection
If the room temperature is lower than 10°C, the compressor ceases operations and
does not resume until room temperature exceeds 12°C.
6.4.7 Forced operation function
Forced cooling mode: The compressor and outdoor fan continue to
run(fi xed at rated frequency), and the indoor fan runs at rated speed.
After running for 30 minutes, the AC will switch to auto mode with a
preset temperature of 24°C.
Forced auto mode: Forced auto mode operates the same as normal
auto mode with a preset temperature of 24°C.
When AC receives signals, such as switch on, switch off , timer on, timer
off , mode setting, temperature setting, fan speed setting, sleeping mode
setting, follow me setting, it will quit the forced operation.
Forced defrosting mode: Press AUTO/COOL button continuously for
5s under forced cooling mode to enter this mode. Indoor fan will stop,
defrosting lamp will light on. Quit this mode and turn off the unit when:
either quit normal defrosting, turn off by RC or Press AUTO/COOL
button continuously for 5s again.
6.4.8 Timer function
Timing range is 24 hours.
Timer on. The machine will turn on automatically when reaching the
setting time.
Timer off . The machine will turn off automatically when reaching the
setting time.
Timer on/off . The machine will turn on automatically when reaching the
setting "on" time, and then turn off automatically when reaching the
setting "off " time.
Timer off /on. The machine will turn off automatically when reaching the
setting "off " time, and then turn on automatically when reaching the
setting "on" time.
The timer function will not change the system operation mode.
The setting time is relative time.
The system will quit the timer function when it has malfunction.
2 2 |
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump (11.2022)
6.4.9 Sleep function
The sleep function is available in cooling, heating or auto mode.
Operation process in sleep mode is as follows:
When cooling, the setting temperature rises 1.8°F (1°C) (be lower than
86°F (30°C)) every one hour, 2 hours later the setting temperature stops
rising and the indoor fan is fi xed at low speed.
When heating, the setting temperature decreases 1.8°F (1°C) (be higher
than 62.6°F (17°C)) every one hour, 2 hours later the setting temperature
stops rising and indoor fan is fi xed at low speed. (Anti-cold wind function
has the priority).
Operation time in sleep mode is 8 hours. After 8 hours, after which, the
unit exits this mode.
Timer setting is available
6.4.10 Auto-restart function
The indoor unit has an auto-restart module that allows the unit to restart
automatically. The module automatically stores the current settings and, in the case
of a sudden power failure, will restore those setting automatically within 3 minutes
after power returns.
If there is a power failure while the unit is running, the compressor starts 3 minutes
after the unit restarts. If the unit was already off before the power failure, the unit
stands by.
6.4.11 Refrigerant leakage detection
The indoor unit will automatically display "EL0C" when it detects refrigerant
leakage.
6.4.12 Louver position memory function
When turning on your unit, the louver will automatically resume its former angle.
6.4.13 46.4°F (8°C) heating (optional)
In heating mode, the temperature can be set to as low as 8°C, preventing the indoor
area from freezing if unoccupied during severe cold weather.
6.4.14 Active Clean function
The Active Clean Technology washes away dust, mold, and grease that may cause
odors when it adheres to the heat exchanger by automatically freezing and then
rapidly thawing the frost. The internal wind wheel then keeps operating to blow-dry
the evaporator, thus preventing the growth of mold and keeping the inside clean.
When this function is turned on, the indoor unit display window appears "CL",
after 20 to 45 minutes, the unit will turn off automatically and cancel Active Clean
function.