Instruction Manual Read this Instruction Manual carefully and keep for future reference. Bedienungsanleitung Lesen Sie sich diese Bedienungsanleitung bitte sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf. Notice d’utilisation Veuillez lire avec attention cette Notice d’utilisation et la conserver pour de futures références. Gebruikershandleiding Lees deze gebruikershandleiding aandachtig en bewaar hem voor naslagdoeleinden.
Page 2
This device features radio interference supression in compliance with valid EC Regulation 2004/108/EC. Dieses Gerät ist funkentstört entsprechend der geltenden EG-Richtlinie 2004/108/EG. Cet appareil est conforme à la directive 2004/108/CE (compatibilité électromagnétique) en vigueur. Questo apparecchio è conforme alla normativa 2004/108/CE vigente in materia di radiodisturbi. Este aparato tiene supresión antiparasitaria según la directiva CEE vigente 2004/108/CE.
Page 3
CAUTIONS This scale is a precision instrument and must be used under certain conditions to ensure accurate measurement. Please observe the following when using this scale. 1.Never disassemble the unit. 2.Use in a vibration-free location that is not exposed to direct sunlight. 3.
IMPORTANT 1. Use on a hard fl at surface confi rming that it is level using the bubble level. 2. To prevent wind from affecting measurement, close cover. 3. Clean using mild detergent. Chemical should not be used. 4. Always use the provided Gem cup. 5.
BEFORE USE ◆ When using with batteries 1. Open the battery cover. 2. Remove the battery cover and insert 4 size AA (LR6) batteries. 3. Replace the battery cover. ◆ When using with AC adaptor 1. Do not use any AC adaptor except those with the following specifi cation. * Only use an AC adaptor with a CE marking 2.
Page 6
CALIBRATING Use the provided 100 g test weight. Press the open Set the Gem cup. Turn the power on. The weighting unit button to open the that was used when cover. the power was turned off last time will be displayed. Default is g.
TARE FUNCTION If TARE is pressed in the middle of weighing, zero (0) appears in the display enabling additional weighing. Place the object to When the stable be measured on the mark is on, press scale. TARE. SWITCHING UNIT When the weighing function is available, press the MODE button and the display switches in the order below.
Page 8
* This scale might have an error within 1% margin when the specimen is too light. Press ON/OFF to turn off. * When the registered weight is insuffi cient, “PC-25” is displayed. In that case, increase the number of specimens to 25 pieces. When the stable mark is displayed, press CAL. If the register is still insuffi...
PROGRAMMING BACKLIT BRIGHTNESS ◆ Default setting is “2”. When the power While pressing Press CAL to display Press MODE to is off MODE press confi rm. ON/OFF. The numeric values Press the TARE to When you have Setting is fi nished. are displayed.
Note: USB Port • USB connecter (mini-B-type 4-pin female) is located on the side of the scale. Caution If you want to use the USB output, you must install the necessary driver onto your PC, available to download from http://www.tanita.com...
Need help?
Do you have a question about the KP-601 and is the answer not in the manual?
Questions and answers