Advertisement

Instruction Manual
Digital Scale
KW-210
The illustrations used in this manual are for illustration purposes
and may differ from the actual product.
Please read this Instruction Manual carefully and keep it handy for future reference.
NOT LEGAL FOR TRADE

Table of contents

Safety Notes........................... 2
Cautions .............................. 3
Name of Parts ........................ 4
Preparation for Use .................. 5
・ Using the AC Adapter .................. 5
・ Location Code Setting .................. 6
・ Unit switching .............................. 6
Operating Instruction ............... 7
・ Standard weighing ........................ 7
・ Tare weighing .............................. 7
Cleaning .............................. 8
Troubleshooting ..................... 9
Product Specification ............ 10

Advertisement

Table of Contents
loading

Summary of Contents for Tanita KW-210

  • Page 1: Table Of Contents

    Instruction Manual Table of contents Digital Scale Safety Notes……………………… 2 Cautions ………………………… 3 KW-210 Name of Parts …………………… 4 Preparation for Use ……………… 5 ・ Inserting/Replacing the Batteries ……… 5 ・ Using the AC Adapter ……………… 5 ・ Auto power off time setting ………… 6 ・...
  • Page 2: Safety Notes

    Safety Notes In this Instruction Manual and description of the equipment, there are various caution symbols that will enable you to use this equipment safely and correctly so as to prevent harm to you and other people as well as loss or damage to your property. Warning This symbol indicates the risk of death or serious injury if the safety instructions are ignored or the equipment is misused.
  • Page 3: Cautions

    Cautions Cautions for Dust Proofing/Water Proofing This scale is designed to meet IEC IP67 (dustproof/waterproof) standards, but when used in certain conditions the dustproof/waterproof functionality of the scale cannot be maintained. Additionally, such conditions may result in damage or malfunctions, and may prevent the scale from measuring accurately.
  • Page 4: Name Of Parts

    Name of Parts Front of Unit Measuring Plate (stainless steel) Upper plate Upper plate fixing screw Accessories Instruction Manual Bellows Hole for upper plate fixing screw Operation buttons Back of Unit Inside the Internal Pressure Inside the Internal Pressure Rubber cap Slide lock (for AC adapter) (catch for opening the battery cover)
  • Page 5: Preparation For Use

    Preparation for Use Inserting /Replacing the Batteries Caution ■ Before opening the battery cover, check that there is no water etc. around the battery cover. ■ After closing the battery cover, be sure to check that all four corners are tightly closed. When the batteries are depleted, “Lo”...
  • Page 6: Auto Power Off Time Setting

    Preparation for Use Auto Power Off Time Setting Auto power off is a function to turn the power off automatically when no operation is executed after the set time has passed. Press and release the    while holding down the    to show        . Note: Press    to toggle between ...
  • Page 7: Operating Instruction

    Operating Instruction ■ Do not place anything on the measuring plate when turning the power on. ■ Do not place any objects to be weighed directly on the upper plate. Always use the provided measuring plate. ■         appears in the display if the total weight of the container and contents exceeds 5000g/11lb (10000g  ...
  • Page 8: Cleaning

    Cleaning Parts other than the internal pressure adjustment rubber 1.Remove the measuring plate, loosen the upper plate fixing screw and  remove the upper plate. 2.Clean the parts.  Wipe gently with a wet cloth. The parts can also be washed using a  sponge or soft cloth soaked in neutral detergent.
  • Page 9: Troubleshooting

    Troubleshooting When you think that the equipment has trouble, check the following symptoms before asking for repair. Symptom Please check. Page ・  When using the equipment with an AC adapter Check connection between the DC jack and the AC adapter jack No display appears even and between the plug and the outlet.
  • Page 10: Product Specification

    Product Specification Type KW-210 Maximum measurement 5kg/1g (11lb/0.05oz) 10kg/2g (22lb/0.1oz) /Minimum display IP67* (When run on batteries) Waterproof Protection Class Power consumption Average 0.02W DC6V LR6(15A,AA) ×4 pieces (not included) Power supply AC adapter - DC6V 200mA centre minus* Approximately 300 hours Battery life D263×W200×H114mm(D10.4×W7.9×H4.5in)
  • Page 11 Notice: These marks can be found out on contaminant-containing Batteries: Pb Pb = Battery contains lead, Cd Cd = Battery contains cadmium, Hg Hg = Battery contains mercury. Not allowed to mix batteries with consumer wastes! As consumer you are legally bound to return used or discharged batteries. You can deposit your old batteries at the public collecting points in your town, or wherever the corresponding batteries are sold and specifically marked collecting boxes have been set up.
  • Page 12 Representative TANITA Europe B.V TANITA India Private Limited TANITA (Shanghai) Trading Co. Ltd. Hoogoorddreef 56-E A-502, Mittal Commercia, Room 8005, 887 Huai Hai Zhong Lu, Shanghai 1101 BE Amsterdam Off. M. V. Road (Andheri Kurla Road), The People’s Republic of China...