Technical information
8.5 Technical specifications
AC power supply
Rated voltage
Permitted voltage range
Rated current
Inrush current I
t
2
Power consumption, typical
Minimum time between two transients
Internal protection
8.5.2

Ambient conditions

8.5.2.1

Transport and storage conditions

Mechanical and climatic conditions for transportation and storage
The requirements regarding transport and storage conditions for the device are more
stringent than those laid down in IEC 60721-3-3. The following requirements apply to the
transport and storage of the device in its original packaging.
The climatic conditions conform to:
● Class 3M3 (mechanical requirements)
● Class 3K3 (climatic requirements)
Type of condition
Drop test (in transport package)
Temperature
Atmospheric pressure
Relative humidity
Sinusoidal vibration in accordance with
IEC 60068-2-6
Shock in accordance with IEC 60068-2-27
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance will render the warranty for the device null and void.
72
Extended versions
230 V AC
100 ... 240 V
200 mA
0.5 A
s
2
40 W
50 s
Electronic
Permitted range
≤ 1 m
From –20 to +60° C
From 1080 to 660 hPa,
Corresponds to an elevation of –1 000 to 3 500 m
From 10 to 90%, without condensation
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
25 g, 6 ms, 1 000 shocks
Industrial Flat Panel IFP1500, IFP1900, IFP2200