  • Page 1 Manual revision August 2015 p/n 65-06-01361...
  • Page 2 Proflame I Wiring/part information Page 4 Proflame I Digital Fireplace Burner Control box wiring Page 5 Proflame I Light & Pilot continues to Sparks (FCM Fuses) Page 6 Proflame I IPI switch issues OR lockout mode Page 7 Proflame I Rear burner & fan issues...
  • Page 3 Mendota Proflame Training Table of Contents PROFLAME II Proflame II Wiring and parts numbers page 13 Proflame II Plug locations & wiring part numbers page 14 Proflame II Wiring Schematic page 15 Proflame II How to check revision code page 16...
  • Page 4 05-02-00356 NG regulator 05-02-00346 LP/Propane Regulator Refer to page 27 for correct p/n for each model Remote PF1 05-02-00361 Battery Cover 05-04-00062 PF receiver 2 way hood 05-02-00380 For complete valve assembly see parts manual *New 2way or 3 way* Flame Rect.
  • Page 5 Flame Rod plugs in here Ground to chassis from bd. Must Be ground 3” from board. Pins 9 8 7 6 5 4 3 2 1 Spark Rod plugs in here Valve resistance, 362 Ohm + or – 10% @ 68 degrees Pin 1 RED, (DXV Non LX units only, battery back up wire) (manual flame regulation) Pin 2 RED, (DC supply voltage 6VDC,...
  • Page 6 1. Light does not work a. Is light turned on via remote ?(finger pointing at button PF1 only) b. Is dimmer in the OFF position? Turn dimmer on, Pro Flame I only i. Make sure dimmer is turned up, not at lowest setting c.
  • Page 7 3. Standing Pilot Switch doesn’t work a. Unit in lockout mode? See page 11 b. Check the standing pilot switch and verify it’s plugged in correct. i. Unhook switch, jumper past switch with a jumper wire ii. Jumper Pin 5 & 6 on Digital Fireplace box, Blue &...
  • Page 8 5. Rear Burner Won’t work (won’t turn on or won’t turn off) a. Is burner on via remote? b. Was pilot was shut off over the summer? Possible insect blocking gas to burner. c. Check to verify 14 pin connector is plugged into back of receiver correctly d.
  • Page 9 7. NO flame/BTU adjustment (flame height) a. Check gas pressure. IN & OUT taps with regulator on high front burner on. Verify pressures are changing from high to low with manometer. b. Make sure Regulator/stepper motor is connected (motorized) c. Verify an insect isn’t restricting gas to burners (pull burners and inspect) d.
  • Page 10 9. Fireplace or Insert does not spark, & fireplace/insert has no blowers or light a. Make sure remote is not in thermostat mode (Smart or On) b. Make sure FCM switch is ON ( - = ON, O = OFF) c.
  • Page 11 Mendota Proflame Training How to reset “lockout” mode Proflame I You may be able to clear lockout mode by turning remote on & then OFF *if not, follow the steps below to clear lockout mode. 1. Power off hand held remote (house icon and temp showing if off).
  • Page 12 *Note, location of the switch in PF1 & PF2 units are the same. The function of the switch in PF2 though is a Master stop switch. In PF2 CPI is control by the remote, please see page 22 FV41 & FV46 switch locations PF1 units CPI/IPI switch PF2 units Master Stop Switch SYNC SWITCH...
  • Page 13 Proflame 2 Proflame 2 Wiring Wiring Diagram For complete Diagram valve assembly see parts manual *New 2way or 3 way* Flame Rect. Rod only 05-04-00069 2 way hood 05-04-00062 triangle or 2 way hood ONLY Refer to page 29 for correct p/n for each model Master Stop switch 05-02-00351...
  • Page 14 X10 & X11 Power to fan and light chassis of unit is tied into ground Bussmann S506 (ties into green ground wire) Wire harness p/n 10-03-00130 Mendota 10-08-00151 X1 AC power to board Grainger p/n = 2ABY8 Wire harness p/n 10-03-00129 Radio Shack p/n = 55048557...
  • Page 15 Proflame 2 Wiring Schematic Spark Rectification Master Stop Switch Error Code LED Flashing...
  • Page 16 Proflame 2 Control Board Back of PF2 control board p/n 05-02-00381 (Revision Code in parenthesis) *When installing a Mendota* Always remove the logs from foam packaging & set them up at the time of start up along with train home owner in proper use of fireplace and remote operation.
  • Page 17: Sync Button

    How to sync remote to fireplace or insert PF2 1. Install batteries into remote, make sure AC power is turned on to unit 2. Press sync button on unit, you should hear module chime, see page 12 3. Press the ON/Off button on remote, you should hear chime •...
  • Page 18 Mendota Proflame Training 1. Fireplace or insert does not work a. Check for all 3 (Thermostat mode via remote? Master Stop switch? Lockout mode?) b. Does the remote communicate with fireplace? You should have light and blower in OFF thermostat mode, even when in the lockout mode.
  • Page 19 Mendota Proflame Training Burner Problems 2. Pilot lights & continues to spark OR pilot keeps sparking all the time and doesn’t lit. Is the gas turned on to the fireplace? Possible Spider mite ? Or blockage in air/gas port? Or Inswool/rock wool in pilot?
  • Page 20 Mendota Proflame Training Blower will not work on fireplace or insert. Make sure blowers are turned on via remote not off. Put remote in “OFF” THERMOSTAT mode, do blowers work? Note, blowers won’t turn on until unit has been on 5 minutes in “Smart” or “On”...